logo
  • Where we operate
    • Markets
      • Concentrated Solar Power
      • Combined Cycle Power Plants
      • Combined Heat and Power
    • Applications
      • Our Applications
      • Turbine Bypass System
      • Boiler Attemperator
      • Heater Bypass System
      • Condensate Recirculation
      • Deaerator Level Control
      • Boiler Feedwater Startup
      • Boiler Feedwater Pump Recirculation
      • Soot Blower Steam Service
      • Vent to atmosphere
  • What we do
    • Products
      • Our Products
      • Valves
        • BVT-TB steam conditioning valve
        • BVT-TBG Steam Conditioning Valve
        • BVT-PB process bypass valve
        • BVT-SC pressure reducing valve
        • BVT-SV stop valve
        • BVT-HB heater bypass valves
        • BVT-BO turbine bypass valve
        • BVT-SCG pressure reduction valve
      • Desuperheaters
        • BVT-DLP steam desuperheater
        • BVT-DLB steam attemperator
        • BVT-DLBS steam attemperator
        • BVT-DLH steam attemperator
        • BVT-DPB1 probe-style attemperator
        • BVT-DP2 probe-style desuperheater
        • BVT-DP3 probe-style desuperheater
        • BVT-DLV venturi desuperheater
      • Actuation & Control
        • BVT-PD pneumatic piston actuator
        • Hydraulics
        • BVT-MSA pneumatic diaphragm actuator
      • Spareparts & Upgrades
        • Spring-loaded Atomizing Nozzles
        • Spare parts and retrofits
        • Pneumatics
        • Hydraulics
        • BVT-Z quick change seat
        • BVT-ZP Zero Passage quick change seat
    • Services & Solutions
      • Plant Engineering
      • Field Service
      • Technical Solutions
      • BVT Remote Assist
      • BVT ranger
    • Success stories
    • Articles
      • Desuperheating
      • Pneumatics
  • About us
    • BVT Sweden
    • Contact
    • Job listings

Pneumatics

Compressed air operates pneumatic actuators and carries control signals through valves, positioners, boosters and tubing. A component must pass enough air at the available pressure to fill or exhaust the actuator as required. Understanding its flow coefficient is a useful first step when comparing components and assessing restrictions in a pneumatic circuit.

What does Cv mean for air?

Cv is a flow coefficient originally defined for water: numerically, it is the flow in US gallons per minute that produces a pressure drop of 1 psi across a component with water near 60 °F. A larger Cv means a higher flow capacity under the same test conditions. Cv is not a connection size, an air volume or a guarantee of actuator stroke time.

Although its definition is based on water, Cv is also used to describe pneumatic valves and accessories. Air is compressible, so its flow cannot be calculated with the liquid square-root pressure-drop relation alone. For air, both inlet and outlet absolute pressures matter, together with temperature, the component’s flow characteristics and the reference conditions used to state the flow rate.

The calculator below estimates an equivalent Cv from a rated air-flow point. It follows a simplified sonic-conductance model. This is an engineering estimate for comparison and preliminary sizing, not a certified Cv test or a substitute for manufacturer flow data.

Air Cv calculator

Enter the flow and the pressures at which that flow is specified. For a rating of 3000 reference litres/min at 6 bar absolute inlet and a 1 bar pressure drop, enter 6 bar(a) inlet and 5 bar(a) outlet. If the rating instead specifies 6 bar gauge, select bar(g) and enter 6 inlet and 5 outlet.

Rated air flow

These are reference-volume flow rates, not actual compressed volume inside a pipe. Check the datasheet’s reference temperature: some suppliers label 20 °C flow as “Nl/min”; use the 20 °C option for those values.

Pressure at the rated flow

Gauge pressures are converted using a fixed atmosphere of 1.01325 bar. For discharge to atmosphere, enter 0 bar(g), or 1.01325 bar(a). Both absolute pressures must be positive, and the outlet must be lower than the inlet.

Flow-model assumption

This simplified model assumes an inlet air temperature of 20 °C. It does not apply an inlet-temperature correction or model humidity changes.

Enable JavaScript to calculate. The equations and worked example below remain available without JavaScript.

How the calculation works

The calculation uses an approximate conversion between Cv and sonic conductance. First, all flow inputs are converted to cubic metres per hour at 20 °C and 1.01325 bar absolute, denoted Q₂₀. Pressures are converted to bar absolute. The model then relates flow, Cv and the pressure-ratio factor φ:

Q20=11.33·Cv·p1·φ,Cv=Q2011.33·p1·φ
SymbolMeaning
Q₂₀Reference air flow in m³/h at 20 °C and 1.01325 bar(a).
p₁ and p₂Inlet and outlet pressure in bar absolute, respectively.
bCritical downstream-to-upstream absolute pressure ratio, default 0.5. This is component-dependent, not a universal air constant.
φFlow factor determined by the absolute pressure ratio r = p₂/p₁.
φ={1if r≤b (choked)1−(r−b1−b)2if b<r<1 (subsonic)

The 11.33 coefficient is a simplified conversion, not a universal ISO conversion from Cv. It is used here with a 20 °C reference convention for consistent results. Manufacturer definitions may differ; measured ISO 6358 sonic conductance and critical pressure ratio are preferable when available.

Worked example

For Q₂₀ = 180 m³/h (3000 L/min at 20 °C), p₁ = 6 bar(a), p₂ = 5 bar(a) and b = 0.5, the ratio is r = 5/6 and φ ≈ 0.74536. Substituting these into the same variable-based equation gives:

Cv=Q2011.33·p1·φ=18011.33·6·0.74536≈3.552

Why pressure ratio and reference conditions matter

In subsonic flow, lowering the outlet pressure increases the flow through a given restriction. Once the model’s critical ratio is reached, the flow becomes choked. Further reducing outlet pressure no longer increases the predicted reference flow at the same inlet pressure and temperature. Increasing inlet absolute pressure can still increase the flow.

A pressure drop of 1 bar does not describe the complete operating point. For example, 6 to 5 bar absolute and 2 to 1 bar absolute both have a 1 bar drop but different pressure ratios and flow capacities. Always record the inlet pressure, outlet pressure and whether the stated values are gauge or absolute.

Reference litres are also not compressed litres. A reference-volume flow represents an amount of air expressed at specified reference conditions. The calculator converts 0 °C normal volumes and 60 °F standard cubic feet to its 20 °C basis using an ideal-gas temperature ratio at the stated reference pressure. Actual line-volume flow is deliberately not offered because it also requires the line temperature and pressure.

Equivalent Cv of an orifice

A plain hole – a drilled restriction, a nozzle, a valve port or a tank outlet – is usually known only by its diameter. Its equivalent Cv can be calculated directly from that diameter. The air accelerates through the hole and the jet contracts just downstream of it (the vena contracta), so the effective flow area is smaller than the drilled area.

Air flowing through a sharp-edged orifice plate in a pipe. The jet contracts to a vena contracta downstream of the hole.
Sharp-edged orifice: the hole diameter d (dimension arrows) sets the geometric area; the jet then contracts (dashed line), which is why Cd is below 1.

When the pressure ratio across the hole is low enough, the air reaches the speed of sound in the hole and the flow is choked. Isentropic flow theory then gives the choked flow per unit of upstream pressure, which is converted to Cv with the same factor as the air Cv calculator above. Inserting the area of a round hole, A = π·d²/4, and the constants for air gives a formula that only depends on the diameter and the discharge coefficient:

Cv=Cd·πd24ρ0·K·κRT0·(2κ+1)κ+12(κ−1)⇒Cv≈0.0497·Cd·dmm2
SymbolMeaning
dHole diameter (m in the full formula, mm in the simplified one)
CdDischarge coefficient, see below
ρ0Reference air density, 1.185 kg/m³ (20 °C, 1.01325 bar(a))
κRatio of specific heats for air, 1.4
RSpecific gas constant for air, 287 J/(kg·K)
T0Reference temperature, 293.15 K
KCv conversion factor, 11.33/(3600·10⁵) ≈ 3.15·10⁻⁸ m³/(s·Pa) per Cv

Example: a 4 mm hole with Cd = 0.8 gives Cv ≈ 0.0497 · 0.8 · 16 ≈ 0.64. Because Cv grows with d², doubling the hole diameter gives four times the Cv.

What is the discharge coefficient?

The discharge coefficient Cd is the ratio between the actual flow through a hole and the ideal flow that would pass if the whole drilled area were used without losses. It accounts mainly for the contraction of the jet and, to a lesser extent, friction at the edge. Cd is always below 1 and depends on the shape of the inlet edge:

CdTypical geometry
0.6 – 0.65Thin sharp-edged plate orifice, subsonic flow (the jet contracts strongly)
≈ 0.8Sharp-edged orifice with choked air flow; a drilled hole in a thicker wall. Common default
0.8 – 0.9Short tube or drilled passage with a chamfered or slightly rounded inlet
0.95 – 0.99Well-rounded nozzle (bell-mouth inlet)
1Ideal nozzle, no losses (theoretical upper limit)
Hole

Enable JavaScript to calculate.

Equivalent Cv of a pipe or hose

A pipe, tube or hose is not just an orifice of the same bore: wall friction reduces its capacity as the length grows. Its equivalent Cv is calculated from only two dimensions, the inside diameter and the length.

A straight hose with its inside diameter and length marked by dimension arrows.
Hose between two fittings: the inside diameter d (right) and the length L (below) are all the calculation needs.

The calculation uses the test-based method of ISO 6358-3:2014, clause 5.3.2.3, which is fitted to flow measurements on tubes at 5 bar inlet pressure. The sonic conductance of the pipe is converted to Cv with the same factor K as above, which gives:

Cv=π·d22000·K·k·L/d+1⇒Cv≈0.0499·dmm2k·L/d+1
k=2.35·10−3·d−0.31(d in m)
SymbolMeaning
dInside diameter (m; mm in the numerator of the simplified formula)
LLength (m)
L/dLength-to-diameter ratio: the larger it is, the more friction lowers Cv
kFriction coefficient, which only depends on the inside diameter (ISO 6358-3, resin tubes)
KCv conversion factor, ≈ 3.15·10⁻⁸ m³/(s·Pa) per Cv

A very short pipe (L → 0) behaves like a nozzle with Cv ≈ 0.05·d². As the length increases, Cv falls roughly in proportion to 1/√L. Example: 5 m of 8 mm bore hose gives k ≈ 0.105, L/d = 625 and Cv ≈ 0.0499 · 64 / √66.6 ≈ 1.16. The expected accuracy is about ±15 %, mainly because of tolerances on the inside diameter.

Critical back-pressure ratio of a pipe or hose

The critical back-pressure ratio b is the outlet-to-inlet ratio of absolute pressures at which the flow becomes choked: if the outlet pressure falls below b times the inlet pressure, the flow no longer increases. For a valve, b is often taken as a fixed value such as 0.5. For piping it is not fixed; it follows directly from the conductance and the bore (ISO 6358-3):

b=4.8·102·Cpiped2=0.754k·L/d+1,m=0.58−0.1·b,Δpc=0

Substituting C shows that b depends only on k·L/d. A short, wide hose chokes early (b ≈ 0.75), while long, thin tubing keeps flowing well below half the inlet pressure (b clearly under 0.5). For 1 m of hose this gives roughly:

Inner diameterb (1 m hose)
1/4″ (6.35 mm)0.45
1/2″ (12.7 mm)0.58
1″ (25.4 mm)0.66
SymbolMeaning
bCritical back-pressure ratio (absolute pressures)
mSubsonic index, which shapes the flow curve between choked flow and zero flow; given for reference
ΔpcCracking pressure: zero for a pipe, since it has no valve element to open
kFriction coefficient: 2.35·10⁻³·d⁻⁰·³¹ for resin tubes (closest match for smooth-bore rubber hose), 3.61·10⁻³·d⁻⁰·³¹ for steel tubes

A maximum error of about ±15 % can be expected, mainly due to inside-diameter tolerances. No fitting, bend or coupling losses are included.

Pipe, tube or hose

Enable JavaScript to calculate.

Equivalent Cv of components in series

When air passes through several components one after another – for example a solenoid valve, a hose, a booster and a silencer – they share the available pressure drop.

Three components connected in series replaced by a single equivalent component.
A valve, a hose and a second component in series (top) behave like one equivalent component (bottom, dashed) whose Cv is smaller than any of them.

For a quick estimate, the series elements combine as:

1Cv,eq2=∑i=1n1Cv,i2⇒Cv,eq=(∑i=1n1Cv,i2)−1/2

The combined value is always lower than the smallest individual value: two equal components in series give 1/√2 ≈ 0.71 of the Cv of one. Use the orifice and pipe calculators above to convert holes and hoses to Cv before adding them here.

This is an approximation. A more accurate result is obtained with the full ISO 6358-3 series method, which marches the pressure element by element and finds the flow by bisection, additionally accounting for each element’s critical pressure ratio.

Component Cv values (leave unused rows empty)

Enable JavaScript to calculate.

Required air tank volume

An air tank (receiver) can operate an actuator when no continuous supply is available, for example for fail-safe strokes. The tank starts at supply pressure and loses pressure on every stroke as it fills the actuator chamber, which starts at atmospheric pressure.

An air tank connected through a valve to a pneumatic cylinder with piston and piston rod.
The tank (left) feeds the cylinder through a valve. The air-filled chamber (light blue) grows by the stroke s (top dimension). The piston diameter D (right dimension) and, when the rod side is filled, the rod diameter dr (marked on the rod) set the area.

The chamber volume per stroke is the effective piston area times the stroke, plus the dead volume of ports and tubing. On the piston (cap) side the full bore area is used; on the rod side the rod area is subtracted:

Apiston=πD24,Arod side=π(D2−dr2)4,Vc=A·s+V0

Treating each fill as an isothermal equalization between tank and chamber (the tank returns to ambient temperature between strokes), the absolute tank pressure after n strokes is:

pn=patm+(psupply−patm)·(VtVt+Vc)n

The tank is usable as long as pn is at least the pressure preq the actuator needs to move its load. Solving for the tank volume that still delivers preq after n strokes gives:

r=(preq−patmpsupply−patm)1/n,Vt=r·Vc1−r
SymbolMeaning
VtAir tank volume
VcActuator chamber volume filled per stroke
D, drPiston diameter and piston rod diameter
sStroke length
V0Dead volume (ports, tubing) at the start of the stroke
psupplyInitial tank pressure
preqLowest pressure that still moves the load; preq = F/A
nNumber of strokes required from the tank

Gauge pressures can be used directly in the ratio, since (p − patm) is the gauge pressure. The model ignores leakage and the time needed to fill the chamber; add a safety margin and check stroke time separately.

Actuator
Pressures and strokes

Enable JavaScript to calculate.

Using the result in a pneumatic circuit

Compare the estimated Cv with manufacturer data at the required operating conditions. A single rated-flow point cannot independently determine both sonic conductance and critical ratio, so the selected b directly affects the inferred Cv. Do not treat the default 0.5 as measured data for every valve, booster, silencer or fitting.

The smallest restriction is important, but several components in series also share the total pressure drop. Tubing length, fittings, filters, directional valves, supply capacity and exhaust restrictions can all affect actuator performance. This calculator does not combine series restrictions or predict actuator stroke time, load response, transient filling or exhaust noise.

For final selection, use tested component flow curves, confirm the applicable flow-reference standard and check the complete circuit. BVT Sweden can help assess pneumatic accessories and replacements and actuation and control requirements.

Smart positioners

A positioner makes the actuator follow the control signal. It compares the requested position (the setpoint) with the measured stem or shaft position and adjusts the air supplied to the actuator until the two agree. Without a positioner, friction, unbalanced process forces and varying supply pressure would make the valve stop in a different place from the one requested.

A smart positioner (digital valve positioner) does this with a microprocessor. It reads a 4–20 mA signal, often with HART, or a fieldbus signal such as Profibus PA or Foundation Fieldbus. It also measures the travel with a position sensor and drives the actuator through an electro-pneumatic converter (an I/P module or piezo pilot valves) and a pneumatic relay or spool. Because the control is digital, a smart positioner can also:

  • calibrate the end positions and tune itself automatically during commissioning,
  • apply travel limits, tight shut-off, split range and flow characteristics (linear, equal percentage or user-defined),
  • run partial stroke tests and report diagnostics such as friction, air leakage, valve signature and total travel,
  • report the actual position back to the control system.

For large actuators or short stroke times, the positioner output is often amplified by volume boosters. The positioner still controls the position, but the boosters change how fast the actuator responds, which affects the tuning described below.

The PID regulator

Inside the positioner, the position is controlled by a regulator, normally of the PID type. The regulator calculates the control error e, the setpoint minus the measured position, and from it the output u that drives the pneumatic stage. The output is the sum of three terms:

u(t)=Kp·e(t)+Ki·∫e(t)dt+Kd·de(t)dt
SymbolMeaning
u(t)Regulator output that controls the air flow to or from the actuator.
e(t)Control error: setpoint minus measured position, usually in % of travel.
KpProportional gain.
KiIntegral gain. Often given as an integral time Ti, where Ki = Kp / Ti.
KdDerivative gain. Often given as a derivative time Td, where Kd = Kp · Td.

P – proportional action

The proportional term reacts to the present error: the further the valve is from the setpoint, the harder the positioner fills or vents the actuator. A higher gain moves the actuator faster towards the setpoint and makes it stiffer against disturbing forces. If the gain is too high, the actuator overshoots and may oscillate around the setpoint (hunting), which also wears the packing and consumes air. If it is too low, the response becomes slow and sluggish.

With proportional action alone, a small error often remains. A constant force, such as packing friction or an unbalanced process force on the plug, needs a constant output to hold the valve, and pure P action only produces an output when there is an error.

I – integral action

The integral term reacts to the accumulated error over time. As long as any error remains, the integral keeps growing and pushes the actuator until the valve reaches the exact setpoint. This removes the remaining offset and gives an accurate final position.

Too much integral action makes the response slower to settle, increases overshoot and can cause slow oscillation. With high static friction it can also cause stick-slip: the integral builds up until the stem breaks free, overshoots, and the cycle repeats. If the actuator is held at an end stop or the air supply is saturated, the integral can grow too large (integrator windup) and cause a large overshoot when the valve is released. Positioners therefore limit the integral and often switch it off inside a small dead band around the setpoint.

D – derivative action

The derivative term reacts to how fast the error is changing. When the actuator moves quickly towards the setpoint, the derivative action counteracts the motion and brakes the actuator before it arrives. This damps the movement, reduces overshoot and allows a higher proportional gain, which gives a faster overall response.

Derivative action amplifies noise and small fluctuations in the position measurement, which can make the output jittery. It is therefore usually filtered and kept small, and some positioners use little or no derivative action.

Effect of increasing each term

IncreaseTypical effect on actuator positioning
PFaster response and better resistance to disturbing forces, but more overshoot and a higher risk of oscillation. Reduces, but does not remove, the remaining error.
IRemoves the remaining error so the valve reaches the exact setpoint, but more overshoot, longer settling and a risk of slow oscillation, stick-slip and windup.
DDamps the motion and reduces overshoot, allowing a higher P gain, but makes the output more sensitive to measurement noise.

Try it: PID step response

Move the sliders to see how each term changes the response when the setpoint steps from 0 to 1 (0 to 100 % of a travel step) at 5 s. The valve and actuator are modelled as a first-order lag with a 2 s time constant and a 1 s dead time. This is an illustration only; real positioners include friction, air supply limits and booster dynamics. The default settings give a fast response with only a small overshoot.

Step response of the actuator position for the selected P, I and D settings, with the setpoint shown as a dashed line.

Enable JavaScript to run the simulation.

Things to try: double Kp to see overshoot and oscillation; set Ki to 0 to see the remaining position error; raise Ki to see slow oscillation; then add Kd to damp an oscillating response.

In practice, most smart positioners tune themselves during automatic calibration. They measure how the actuator responds and select gains for the actual valve, actuator size, friction and air supply. Manual adjustment is mainly needed when the result is too slow or oscillates, for example after adding volume boosters, changing the packing or changing the supply pressure. Increase the gain step by step, and check the response with small and large setpoint steps across the stroke.

BVT Sweden can supply and retrofit smart positioners on existing actuators. See actuation and control.

Frequently asked questions

How fast can a pneumatic actuator stroke a turbine bypass valve?

There is no single figure: the stroke time is a design requirement that the actuator is built to meet. For the BVT-PD pneumatic piston actuator it is set by the cylinder volume, the stroke length, the supply pressure and the flow capacity (Cv) of the pneumatic circuit, where the component with the smallest Cv limits the speed. Fast trip (quick open or quick close) strokes use air stored in an air tank sized for two complete strokes, and volume boosters are added when the positioner alone cannot give the required modulating stroke speed. BVT selects the components by simulation, confirms the stroke times by testing, and recommends a complete stroke test of the quick function every 12 months. See the BVT-PD pneumatic actuator. The air Cv calculator above helps you check which component in the circuit limits the air flow.

Can I calculate Cv from flow and pressure drop alone?

Not reliably for air. You also need the upstream absolute pressure, because the ratio between downstream and upstream pressures controls the flow regime. This calculator asks for both pressures so that their difference and ratio are unambiguous.

Is the result a manufacturer-certified Cv?

No. It is an equivalent Cv inferred from one rated-flow point using a simplified model and the selected critical pressure ratio. A certified Cv or ISO 6358 C and b values require appropriate component testing.

Which flow option should I choose for Nl/min?

Check the supplier's definition. Choose the 0 °C Nl/min option if the stated normal conditions are 0 °C and 1.01325 bar(a). If the supplier uses 20 °C at that pressure, choose the 20 °C L/min option instead. Reference conditions are part of the input, not just a label.

Method reference: rated-flow back-calculation with a simplified Cv-to-sonic-conductance conversion. The pressure-ratio model uses a simplified ISO 6358-style characteristic; it is not a full implementation of a component test standard.

Follow us

Facebook
Linkedin

Our partners

HP Valves B.V.
Key Valve Technologies LTD

Factory Support Office

Industrigatan 1-3
661 32 Säffle
SWEDEN

Sales Office

BVT Sweden AB
Körkarlsvägen 8
SE-653 46 Karlstad
Sweden

Factory Address

Industrigatan 1
661 32 Säffle
Sweden

© 2019 BVT Sweden