IMI CCI valves upgraded to BVT-TB: five process steam reducing stations without vibration
A Swedish pulp and paper mill supplies process steam to its 4 bar and 12 bar steam networks through five pressure reducing stations. The existing IMI CCI VST-ST steam conditioning valves, with built-in steam-assisted evaporation, suffered from vibration and high wear. The mill asked BVT Sweden to replace them with BVT-TB steam conditioning valves.
| Application | Pressure reducing stations, steam to process |
| Number of stations | 5 |
| Steam networks | 4 bar and 12 bar |
| Scope | Replacement of IMI CCI VST-ST valves with BVT-TB, separate BVT-SE steam-assisted evaporation nozzles and downstream diffusers |
The problem
- Vibration in the valves and downstream piping
- High wear on internal parts
The solution
BVT Sweden supplied BVT-TB steam conditioning valves designed for the actual operating conditions of each station. Pressure is reduced in several stages that were chosen for each application, which keeps noise, vibration and wear low across the whole operating range.
Instead of evaporation built into the valve, each station has a separate BVT-SE steam-assisted evaporation nozzle in the valve outlet. Atomizing steam breaks up the cooling water into fine droplets that evaporate quickly. A diffuser installed downstream adds a final pressure drop, which further helps the evaporation and gives stable outlet temperature to the process.

The result
After the upgrade, the five stations run without the vibration problems and with much lower wear. The mill now has reliable process steam supply to both the 4 bar and 12 bar networks, with less maintenance.
Do you have a valve that vibrates, wears quickly or loses temperature control at low loads? BVT ranger helps you find the cause and the right upgrade. You can also read more about the BVT-TB steam conditioning valve.