BVT-BO Turbine Bypass Valve
The BVT-BO is an angle-style steam conditioning valve for turbine bypass, mainly in coal-fired plants. It combines cage-and-plug pressure reduction with water injection through a hollow stem and holes in the plug. Steam and spray water mix inside the cage before flowing into the outlet.
How the BVT-BO works
Plug movement uncovers perforations in the valve cage to control the steam flow and downstream pressure. The steam flow is arranged to push the plug toward its open position. The plug design is optimized to reduce actuating forces, allowing pneumatic actuation where appropriate to the specified duty.
Cooling water passes through a hollow stem and is injected through small holes in the plug. The water mixes with steam inside the cage before the mixture passes through the cage to the outlet. This injection arrangement differs from the outlet-mounted spray nozzles used in other steam-conditioning valve families.
The forged body and pressure-seal bonnet form the pressure-retaining assembly. Material and connections are selected to match the piping and operating conditions. Pressure control, spray-water regulation and actuator response must be specified together for the turbine-bypass operating cases.
Applications and selection
The B-027 brochure describes the BO as a turbine-bypass valve used mainly in coal-fired plants and illustrates a high-pressure bypass position. A bypass provides an alternative route for steam in parallel with a turbine pressure stage and can control downstream pressure and temperature during operation or a turbine trip.
Supply BVT with normal and transient steam conditions, required flow range, downstream pressure and temperature targets, available spray water, connection details, shut-off requirements and actuator functions. The selected bypass route and downstream equipment determine the complete-system requirements.
Key features
- Angle-style forged valve body.
- Hollow-stem and plug water injection.
- Pressure-seal bonnet.
- Valve trim designed for low actuating forces and thermal cycling.
- Pneumatic, hydraulic or electrical actuation.
- Expanded outlet and live-load gland packing options.
Specifications
| Pressure class | Up to ANSI 4500; higher rating on request |
|---|---|
| Design temperature | 620 °C standard; 650 °C on request |
| Leakage class | ANSI Class III, IV, V; MSS SP 61 |
| Complete-valve rangeability | Up to 25:1 |
| Body material | Forged material adapted to the connecting pipe material |
| Actuation | Pneumatic, hydraulic or electrical |
| Water injection | Through hollow stem and holes in the plug |
| Options | Expanded outlet; live-load gland seal packing |
Confirm the selected pressure-temperature rating and material for the actual valve. The 650 °C design is on request, not the standard rating, and published product-family maxima must not be assumed to apply simultaneously.
Actuation options
The BVT-BO can be equipped with pneumatic, electrical or hydraulic actuation. Select the actuator to overcome the valve forces and meet the required stroke time, control function and safe-position requirements. The balanced plug reduces the actuating force needed by the valve.
Pneumatic actuation
BVT supplies pneumatic piston actuators selected for the valve duty. Published options include double-acting and single-acting cylinders, spring-open or spring-close arrangements, and top-mounted or side-mounted handwheels. The valve brochures describe an air supply of 4 to 10 bar; use the actual actuator’s pneumatic diagram for the required setting and permitted limits.
| Cylinder configurations | Double acting or single acting; spring open or spring close |
|---|---|
| Published air supply | 4 to 10 bar, subject to the supplied actuator specification |
| Standard accessory | Air filter regulator |
| Options | Quick-open/close valves, limit switches, position transmitter, air locks and volume boosters |
Electrical and hydraulic alternatives
Electrical and hydraulic actuation are available for the product family. Confirm the final actuator, accessories, control interface and required fail-safe behavior with BVT for the selected valve and operating cases. Do not apply a pneumatic actuator’s air-supply data to another actuator type.
Installation and service guidance
Use product manual M-026, BVT general instructions M-001 and the drawings supplied for the installation. These notes are an overview, not a substitute for the equipment-specific instructions. Installation, commissioning and service must be carried out by trained personnel within the specified service conditions.
Product-specific installation requirements
Verify the specified steam flow direction, connections, spray-water supply and actuator arrangement against the supplied drawings. Provide access to the bonnet, stem coupling and water-injection components for inspection and service.
Product manual M-026 covers the BO pressure-seal bonnet, trim, gland and actuator interfaces. The valve or yoke must never be lifted using the actuator or its lifting eyes. Use the equipment-specific lifting and maintenance instructions rather than procedures from another valve model.
Before commissioning
Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.
Safe access and maintenance planning
Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.
Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.
Frequently asked questions
- What does the BVT-BO turbine bypass valve do?
- It reduces steam pressure and temperature in an angle-style valve. B-027 describes turbine-bypass applications, mainly in coal-fired plants, and illustrates a high-pressure bypass position.
- How does the BO inject cooling water?
- Water passes through a hollow stem and holes in the plug. It mixes with steam inside the cage before the mixture enters the valve outlet.
- Which design temperatures are published?
- B-027 lists 620 °C as standard and 650 °C on request. Confirm the selected material and combined pressure-temperature envelope for the actual order.
- What pressure class and rangeability are listed?
- The brochure lists pressure class up to ANSI 4500, with higher ratings on request, and complete-valve rangeability up to 25:1.
- Which actuator types can be used?
- Pneumatic, hydraulic and electrical actuation are available. Select the actuator and accessories for the required force, stroke time, control function and safe-position behavior.
- Which manual applies?
- Use product manual M-026, general instructions M-001 and the supplied installation drawings, together with the documentation for the selected actuator and accessories.
Product documentation
Download B-027 BVT-BO brochure (PDF)
For installation and service, use product manual M-026 together with BVT general instructions M-001 and the documentation supplied for your equipment. Contact BVT for the applicable manual revision, installation drawings and spare parts identification.
Related BVT products
Contact BVT Sweden with the operating conditions and required functionality for application-specific selection.