logo
  • Where we operate
    • Markets
      • Concentrated Solar Power
      • Combined Cycle Power Plants
      • Combined Heat and Power
    • Applications
      • Our Applications
      • Turbine Bypass System
      • Boiler Attemperator
      • Heater Bypass System
      • Condensate Recirculation
      • Deaerator Level Control
      • Boiler Feedwater Startup
      • Boiler Feedwater Pump Recirculation
      • Soot Blower Steam Service
      • Vent to atmosphere
  • What we do
    • Products
      • Our Products
      • Valves
        • BVT-TB steam conditioning valve
        • BVT-TBG Steam Conditioning Valve
        • BVT-PB process bypass valve
        • BVT-SC pressure reducing valve
        • BVT-SV stop valve
        • BVT-HB heater bypass valves
        • BVT-BO turbine bypass valve
        • BVT-SCG pressure reduction valve
      • Desuperheaters
        • BVT-DLP steam desuperheater
        • BVT-DLB steam attemperator
        • BVT-DLBS steam attemperator
        • BVT-DLH steam attemperator
        • BVT-DPB1 probe-style attemperator
        • BVT-DP2 probe-style desuperheater
        • BVT-DP3 probe-style desuperheater
        • BVT-DLV venturi desuperheater
      • Actuation & Control
        • BVT-PD pneumatic piston actuator
        • Hydraulics
        • BVT-MSA pneumatic diaphragm actuator
      • Spareparts & Upgrades
        • Spring-loaded Atomizing Nozzles
        • Spare parts and retrofits
        • Pneumatics
        • Hydraulics
        • BVT-Z quick change seat
        • BVT-ZP Zero Passage quick change seat
    • Services & Solutions
      • Plant Engineering
      • Field Service
      • Technical Solutions
      • BVT Remote Assist
      • BVT ranger
    • Success stories
    • Articles
      • Desuperheating
      • Pneumatics
  • About us
    • BVT Sweden
    • Contact
    • Job listings

BVT-DLB Ring-Style Steam Attemperator

The BVT-DLB is a ring-style attemperator for controlling superheat in boilers and HRSGs. Multiple spring-loaded atomizing nozzles inject cooling water into the steam flow, and a welded flow-profiling liner supports evaporation. It can be selected for inter-stage or final-stage temperature control.

BVT-DLB ring-style steam attemperator with welded liner and multiple nozzle assemblies
BVT-DLB ring-style steam attemperator with welded liner and multiple nozzle assemblies

How the BVT-DLB works

Attemperation controls the degree of superheat by injecting water into the steam. In the DLB, a series of spring-loaded nozzles distributes the water in the pipe. An external water control valve meters the spray water according to the required cooling duty.

The welded flow-profiling liner improves the conditions for evaporation while protecting the steam pipe from thermal stress. Nozzle count, sizing and the selected water valve must work together across the intended operating range. The published rangeability is determined by the water valve, not a universal steam-turndown figure for the attemperator alone.

The DLB and floating-liner products serve related temperature-control duties but use different liner constructions. DLB has a welded liner; DLH and DLBS have unwelded floating liners. Choose the assembly for the plant's thermal duty and use the correct product-specific service instructions.

Applications and selection

An inter-stage attemperator is installed between superheater stages to protect downstream superheater pipes from excessive temperature. A final-stage unit can regulate the outlet temperature of the boiler or HRSG and help control the rate at which turbine-inlet temperature rises, as described in B-012.

Selection must include steam and water flow ranges, pressures and temperatures, required outlet conditions, pipe dimensions and materials, available evaporation distance and expected transient duty. Review sensor location and drainage as part of the complete installation rather than selecting the attemperator solely from a pressure class.

Key features

  • Welded flow-profiling liner as standard.
  • Multiple spring-loaded atomizing nozzles.
  • Designed for large spray-water duties and even water distribution.
  • Nozzle and spring options for demanding thermal conditions.
  • Low steam-line pressure drop as described in B-012.

Specifications

BVT-DLB technical data from B-012 and M-007. Confirm the selected configuration against the order documentation.
RangeabilityDetermined by the external spray-water control valve
Pressure classEN PN 16-320; ASME 150-2500
Steam design temperature630 °C
Water design temperature250 °C
LinerWelded flow-profiling liner
Nozzle arrangementMultiple spring-loaded atomizing nozzles
Pipe and liner materialsAdapted to the connecting pipe materials
Typical positionsInter-stage or final-stage boiler/HRSG attemperation

Confirm the actual pressure-temperature envelope, materials and operating duty for the supplied DLB. Published product-family temperature limits must not be treated as the rating of every configuration.

Installation and service guidance

Use product manual M-007, BVT general instructions M-001 and the drawings supplied for the installation. These notes are an overview, not a substitute for the equipment-specific instructions. Installation, commissioning and service must be carried out by trained personnel within the specified service conditions.

Product-specific installation requirements

Install the DLB according to the supplied flow direction, nozzle arrangement and piping drawing. Provide the required downstream mixing and evaporation distance before temperature measurement, and review the water control valve and drainage together with the attemperator.

M-007 covers the combined DLP/B/H/PD family. Use the sections appropriate to the delivered DLB and its welded liner. Pipeline welding, cleaning and commissioning require qualified personnel and the specified preparations; do not transfer procedures from a floating-liner product without confirmation.

Before commissioning

Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.

Safe access and maintenance planning

Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.

Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.

Frequently asked questions

What is the DLB attemperator used for?
It controls superheat in a boiler or HRSG by spray-water injection. B-012 describes inter-stage protection of superheater pipes and final-stage control of boiler or HRSG outlet steam temperature.
Does the DLB have a floating liner?
No. The DLB has a welded flow-profiling liner. The DLH and DLBS use different, unwelded floating-liner designs.
How is water flow controlled?
A separate spray-water control valve meters water to the spring-loaded nozzles. The published rangeability is determined by that valve, subject to complete-system selection.
What temperatures are listed in B-012?
The brochure lists steam design temperature of 630 °C and water design temperature of 250 °C. Confirm the combined pressure-temperature rating and selected materials of the actual unit.
Which pressure classes are available?
B-012 lists EN PN 16-320 and ASME 150-2500. Select the required class and material using the project pressure-temperature conditions and equipment documentation.
Which manual applies to the DLB?
Use the applicable DLB sections of combined product manual M-007, general instructions M-001 and the drawings and commissioning instructions supplied with the equipment.

Product documentation

Download B-012 BVT-DLB brochure (PDF)

For installation and service, use product manual M-007 together with BVT general instructions M-001 and the documentation supplied for your equipment. Contact BVT for the applicable manual revision, installation drawings and spare parts identification.

Related BVT products

  • BVT-DLH floating-liner attemperator
  • BVT-DLP process-steam desuperheater

Contact BVT Sweden with the operating conditions and required functionality for application-specific selection.

Follow us

Facebook
Linkedin

Our partners

HP Valves B.V.
Key Valve Technologies LTD

Factory Support Office

Industrigatan 1-3
661 32 Säffle
SWEDEN

Sales Office

BVT Sweden AB
Körkarlsvägen 8
SE-653 46 Karlstad
Sweden

Factory Address

Industrigatan 1
661 32 Säffle
Sweden

© 2019 BVT Sweden