logo
  • Where we operate
    • Markets
      • Concentrated Solar Power
      • Combined Cycle Power Plants
      • Combined Heat and Power
    • Applications
      • Our Applications
      • Turbine Bypass System
      • Boiler Attemperator
      • Heater Bypass System
      • Condensate Recirculation
      • Deaerator Level Control
      • Boiler Feedwater Startup
      • Boiler Feedwater Pump Recirculation
      • Soot Blower Steam Service
      • Vent to atmosphere
  • What we do
    • Products
      • Our Products
      • Valves
        • BVT-TB steam conditioning valve
        • BVT-TBG Steam Conditioning Valve
        • BVT-PB process bypass valve
        • BVT-SC pressure reducing valve
        • BVT-SV stop valve
        • BVT-HB heater bypass valves
        • BVT-BO turbine bypass valve
        • BVT-SCG pressure reduction valve
      • Desuperheaters
        • BVT-DLP steam desuperheater
        • BVT-DLB steam attemperator
        • BVT-DLBS steam attemperator
        • BVT-DLH steam attemperator
        • BVT-DPB1 probe-style attemperator
        • BVT-DP2 probe-style desuperheater
        • BVT-DP3 probe-style desuperheater
        • BVT-DLV venturi desuperheater
      • Actuation & Control
        • BVT-PD pneumatic piston actuator
        • Hydraulics
        • BVT-MSA pneumatic diaphragm actuator
      • Spareparts & Upgrades
        • Spring-loaded Atomizing Nozzles
        • Spare parts and retrofits
        • Pneumatics
        • Hydraulics
        • BVT-Z quick change seat
        • BVT-ZP Zero Passage quick change seat
    • Services & Solutions
      • Plant Engineering
      • Field Service
      • Technical Solutions
      • BVT Remote Assist
      • BVT ranger
    • Success stories
    • Articles
      • Desuperheating
      • Pneumatics
  • About us
    • BVT Sweden
    • Contact
    • Job listings

BVT-DLBS Floating-Liner Steam Attemperator

The BVT-DLBS is a steam attemperator with a single spring-loaded spray-water nozzle and an unwelded floating liner. It controls superheat in boilers and HRSGs using water metered by an external control valve. The liner protects the steam pipe and can move as its material expands.

BVT-DLBS steam attemperator with floating liner and a single water-injection nozzle
BVT-DLBS steam attemperator with floating liner and a single water-injection nozzle

How the BVT-DLBS works

Spray water is injected perpendicular to the superheated steam through the spring-loaded atomizing nozzle. The water absorbs heat as it warms and evaporates, reducing the steam's superheat. The required water flow is controlled by a separate valve selected for the operating duty.

The floating liner protects the surrounding pipe from thermal stresses and acts as a flow profiler. Increased relative steam velocity near the nozzle improves evaporation conditions. Because the liner is installed without welding, it can accommodate material expansion rather than relying on a welded liner joint.

The DLBS has its own single-nozzle arrangement. It should not be described as a multi-nozzle DLH, or serviced using assumptions taken from a welded-liner desuperheater. Match the nozzle, water valve, pipe geometry and downstream temperature measurement to the actual operating range.

Applications and selection

B-014 describes attemperation for boilers and Heat Recovery Steam Generators and illustrates inter-stage and final-stage locations. The appropriate position and temperature target depend on the superheat-control requirements of the connected equipment.

For selection, provide the full steam and spray-water conditions, temperature targets, cyclic operating duty and proposed pipe arrangement. The brochure lists cycling capability up to 6300 cycles over 25 years. Confirm the applicable cycle definition and project conditions rather than treating this as a guarantee for every installation.

Key features

  • Single spring-loaded atomizing nozzle.
  • Inconel 718 nozzle material.
  • Unwelded floating flow-profiling liner.
  • External water control selected for the application.
  • Design intended to accommodate thermal expansion and cycling.

Specifications

BVT-DLBS technical data from B-014. Confirm the selected configuration against the order documentation.
Nozzle arrangementSingle spring-loaded atomizing nozzle
Nozzle materialInconel 718
RangeabilityDetermined by the external spray-water control valve
Steam design pressure200 bar(g)
Water design pressure320 bar(g)
Steam design temperature630 °C
Water design temperature250 °C
Published cycling capabilityUp to 6300 cycles / 25 years; confirm project duty
Recommended installationHorizontal, or vertical with steam flowing upwards

All product-specific ratings here follow B-014. Confirm the selected pressure-temperature envelope, cyclic duty and installation details from the documentation supplied for the actual DLBS assembly.

Installation and service guidance

Use BVT general instructions M-001 and the DLBS-specific instructions and drawings supplied for the installation. Contact BVT for the applicable product documentation before work begins. These notes are an overview, not a substitute for equipment-specific procedures; installation, commissioning and service must be carried out by trained personnel within the specified service conditions.

Product-specific installation requirements

B-014 recommends horizontal installation or vertical installation with steam flowing upwards. Preserve the floating-liner arrangement shown on the supplied drawing and provide the required access for inspection of the nozzle and liner.

Do not apply welded-liner repair instructions to this unwelded assembly. Review water quality, drainage, mixing and temperature-sensor placement as parts of the complete temperature-control system. Obtain the DLBS-specific service procedure before inspecting or removing pressure-retaining components.

Before commissioning

Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.

Safe access and maintenance planning

Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.

Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.

Frequently asked questions

How many nozzles does the DLBS use?
B-014 describes a single spring-loaded atomizing nozzle. This distinguishes the DLBS from the multi-nozzle DLH arrangement.
Is the liner welded into the pipe?
No. The floating liner is installed without welding and can move with thermal expansion. It also protects the pipe from thermal stress and profiles the steam flow.
How is the spray water regulated?
An external spray-water control valve regulates the water flow. That valve determines the published rangeability, while the complete cooling performance also depends on steam conditions and evaporation distance.
What design limits are published?
B-014 lists 200 bar(g) steam design pressure, 320 bar(g) water design pressure, 630 °C steam design temperature and 250 °C water design temperature. Confirm the combined rating for the selected unit.
Can it be installed vertically?
B-014 recommends horizontal installation or vertical installation with steam flowing upwards. Different arrangements require an installation-specific review with BVT.
Which service instructions should be used?
Use M-001 for general safety and request the applicable DLBS-specific instructions and drawings from BVT. A different product's welded-liner procedure is not a substitute for the floating-liner assembly instructions.

Product documentation

Download B-014 BVT-DLBS brochure (PDF)

Use brochure B-014 for DLBS product data and M-001 for general installation and safety guidance. Request the applicable DLBS-specific installation and service instructions, drawings and manual revision from BVT. General instructions do not replace the documentation for the delivered floating-liner assembly.

Related BVT products

  • BVT-DLH multi-nozzle floating-liner attemperator
  • BVT-DLB welded-liner attemperator

Contact BVT Sweden with the operating conditions and required functionality for application-specific selection.

Follow us

Facebook
Linkedin

Our partners

HP Valves B.V.
Key Valve Technologies LTD

Factory Support Office

Industrigatan 1-3
661 32 Säffle
SWEDEN

Sales Office

BVT Sweden AB
Körkarlsvägen 8
SE-653 46 Karlstad
Sweden

Factory Address

Industrigatan 1
661 32 Säffle
Sweden

© 2019 BVT Sweden