logo
  • Where we operate
    • Markets
      • Concentrated Solar Power
      • Combined Cycle Power Plants
      • Combined Heat and Power
    • Applications
      • Our Applications
      • Turbine Bypass System
      • Boiler Attemperator
      • Heater Bypass System
      • Condensate Recirculation
      • Deaerator Level Control
      • Boiler Feedwater Startup
      • Boiler Feedwater Pump Recirculation
      • Soot Blower Steam Service
      • Vent to atmosphere
  • What we do
    • Products
      • Our Products
      • Valves
        • BVT-TB steam conditioning valve
        • BVT-TBG Steam Conditioning Valve
        • BVT-PB process bypass valve
        • BVT-SC pressure reducing valve
        • BVT-SV stop valve
        • BVT-HB heater bypass valves
        • BVT-BO turbine bypass valve
        • BVT-SCG pressure reduction valve
      • Desuperheaters
        • BVT-DLP steam desuperheater
        • BVT-DLB steam attemperator
        • BVT-DLBS steam attemperator
        • BVT-DLH steam attemperator
        • BVT-DPB1 probe-style attemperator
        • BVT-DP2 probe-style desuperheater
        • BVT-DP3 probe-style desuperheater
        • BVT-DLV venturi desuperheater
      • Actuation & Control
        • BVT-PD pneumatic piston actuator
        • Hydraulics
        • BVT-MSA pneumatic diaphragm actuator
      • Spareparts & Upgrades
        • Spring-loaded Atomizing Nozzles
        • Spare parts and retrofits
        • Pneumatics
        • Hydraulics
        • BVT-Z quick change seat
        • BVT-ZP Zero Passage quick change seat
    • Services & Solutions
      • Plant Engineering
      • Field Service
      • Technical Solutions
      • BVT Remote Assist
      • BVT ranger
    • Success stories
    • Articles
      • Desuperheating
      • Pneumatics
  • About us
    • BVT Sweden
    • Contact
    • Job listings

BVT-DLP Ring-Style Steam Desuperheater

The BVT-DLP is a ring-style desuperheater for reducing superheated steam temperature by spray-water injection. A series of spring-loaded nozzles distributes water across the steam pipe, while a welded flow-profiling liner protects the pipe from thermal stress and supports evaporation. Water flow is controlled by an external valve.

BVT-DLP ring-style steam desuperheater with water manifold and nozzle assemblies
BVT-DLP ring-style steam desuperheater with water manifold and nozzle assemblies

How the BVT-DLP works

Spray water is injected perpendicular to the steam flow through several spring-loaded atomizing nozzles. The number of nozzles is selected for the steam-pipe diameter so the spray is distributed over the pipe cross-section. Nozzle springs are selected and preloaded to avoid flashing at the nozzle opening.

The welded liner has two functions: shielding the steam pipe from direct thermal loading and profiling the flow. By increasing the relative steam velocity near the nozzles, it improves the conditions for droplet evaporation. The liner is a welded design, unlike the floating liners used in the DLH and DLBS product families.

An external spray-water control valve meters the cooling water. Published rangeability is therefore determined by that valve, while the actual steam-cooling performance also depends on atomization, steam flow and available evaporation distance. Select the water valve and desuperheater as parts of the same temperature-control system.

Applications and selection

B-010 shows the DLP in bypass-to-process service, including turbine extraction and exhaust desuperheating. It is intended for process steam duties requiring distributed water injection and a flow-profiling liner, with the nozzle arrangement matched to the pipe and operating conditions.

Provide BVT with the full steam and water operating ranges, required outlet temperature, pipe materials and dimensions, available straight pipe and temperature-measurement locations. The product is designed for large spray-water duties, but the appropriate number and size of nozzles remain application-specific.

Key features

  • Multiple spring-loaded atomizing nozzles.
  • Welded flow-profiling liner as standard.
  • Nozzle count selected for the pipe diameter.
  • Designed for large spray-water flow and even distribution.
  • Low steam-line pressure drop as described in B-010.

Specifications

BVT-DLP technical data from B-010 and M-007. Confirm the selected configuration against the order documentation.
RangeabilityDetermined by the external spray-water control valve
Pressure classEN PN 16-320; ASME 150-2500
Steam design temperature630 °C
Water design temperature250 °C
LinerWelded flow-profiling liner
NozzlesMultiple spring-loaded atomizing nozzles
Steam pipe and liner materialsAdapted to the connecting pipe materials
High-temperature optionsInconel nozzle and spring options, selected for the duty

Pressure classes and design temperatures describe the product family. Confirm the actual pressure-temperature envelope, materials and water duty for the selected equipment; do not combine every published maximum without a design review.

Installation and service guidance

Use product manual M-007, BVT general instructions M-001 and the drawings supplied for the installation. These notes are an overview, not a substitute for the equipment-specific instructions. Installation, commissioning and service must be carried out by trained personnel within the specified service conditions.

Product-specific installation requirements

Follow the supplied flow direction, pipe alignment and nozzle arrangement. M-007 requires qualified welding and suitable preparation before the desuperheater is welded into the pipeline. Use the supplied commissioning instructions and required protective tools rather than exposing the operating internals to an unreviewed cleaning procedure.

Provide access to the nozzles, water manifold and liner inspection locations. M-007 describes liner and weld inspections; use the procedures appropriate to the delivered welded-liner design. If the liner or connected pipework shows cracking, have BVT evaluate the system and temperature-control conditions.

Before commissioning

Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.

Safe access and maintenance planning

Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.

Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.

Frequently asked questions

What is the BVT-DLP used for?
It reduces process-steam temperature by injecting water through multiple nozzles. B-010 illustrates bypass-to-process duties including turbine extraction and exhaust desuperheating.
How is spray-water flow controlled?
An external water control valve meters the spray water. Its selection determines the published rangeability of the arrangement; complete-system cooling performance also depends on the steam and piping conditions.
What is the purpose of the liner?
The welded liner protects the steam pipe from thermal stress and profiles the flow near the nozzles, increasing relative steam velocity and supporting water-droplet evaporation.
How many nozzles are used?
The number is selected for the steam-pipe diameter and required water distribution. The nozzles are spring loaded, and the springs are selected and preloaded for the injection duty.
What temperatures are published?
B-010 lists a steam design temperature of 630 °C and water design temperature of 250 °C. Confirm the pressure-temperature envelope and materials of the actual supplied unit.
Which manual covers the DLP?
M-007 is the combined BVT-DLP/B/H/PD product manual. Use the sections appropriate to the supplied DLP design together with M-001 and the order-specific installation and commissioning documentation.

Product documentation

Download B-010 BVT-DLP brochure (PDF)

For installation and service, use product manual M-007 together with BVT general instructions M-001 and the documentation supplied for your equipment. Contact BVT for the applicable manual revision, installation drawings and spare parts identification.

Related BVT products

  • BVT-DLB boiler attemperator
  • BVT-DLH floating-liner attemperator

Contact BVT Sweden with the operating conditions and required functionality for application-specific selection.

Follow us

Facebook
Linkedin

Our partners

HP Valves B.V.
Key Valve Technologies LTD

Factory Support Office

Industrigatan 1-3
661 32 Säffle
SWEDEN

Sales Office

BVT Sweden AB
Körkarlsvägen 8
SE-653 46 Karlstad
Sweden

Factory Address

Industrigatan 1
661 32 Säffle
Sweden

© 2019 BVT Sweden