BVT-DLV Venturi Desuperheater
The BVT-DLV is a compact venturi-style steam desuperheater with a fixed spray-water nozzle. It is used in industrial and municipal power, district heating and process applications. An external spray-water control valve regulates the water flow, while the venturi increases steam velocity around the nozzle.
How the BVT-DLV works
A static nozzle injects cooling water in the direction of the superheated steam. The venturi increases steam velocity over the nozzle, improving the evaporation of water droplets and reducing the risk of spray water reaching the downstream pipe wall. The nozzle and venturi form a compact injection assembly.
The desuperheater has no moving control parts in its injection assembly. Water regulation is handled by an external spray-water control valve, which must be selected for the operating conditions and required control range. The published rangeability of the DLV arrangement is therefore determined by that water valve rather than a moving valve inside the desuperheater.
B-026 lists a maximum pressure drop over the nozzle of 5 bar, also stated as 70 psi. Treat this as a nozzle pressure-drop limit, not as the pressure rating of the steam line. Connection pressure class, water-valve duty and the pressure difference available for injection are separate selection considerations.
Applications and selection
The DLV is intended for steam temperature reduction in industrial or municipal power generation, district heating and the process industry. Its fixed-nozzle layout and lack of moving injection parts suit installations seeking a small, mechanically simple desuperheater, provided the external water control and piping arrangement are correctly selected.
The brochure describes accurate temperature control down to 8 °C above saturation. Achieving an outlet-temperature target requires a review of steam and water conditions, control-valve selection and available evaporation distance. Provide BVT with the full operating range rather than assuming that the closest approach to saturation is available at every flow condition.
Key features
- Fixed nozzle aligned with the steam flow.
- Venturi increases steam velocity at the injection point.
- No moving parts in the desuperheater injection assembly.
- External spray-water control valve selected for the application.
- Compact design for power, district heating and process steam duties.
Specifications
| Rangeability | Determined by the external spray-water control valve |
|---|---|
| Pressure class | ASME 600-2500 |
| Steam connection size | Up to 6 inches |
| Water connection size | Up to 2 inches |
| Maximum pressure drop over nozzle | 5 bar / 70 psi, as stated in B-026 |
| Nozzle | Fixed |
| Published temperature-control capability | Down to 8 °C / 15 °F above saturation, subject to application selection |
| Connection arrangements covered by M-022 | Flanged and welded designs |
The nozzle pressure drop is not the steam-line pressure rating. Confirm the selected pressure-temperature envelope and the achievable outlet conditions with BVT for the actual operating range.
Installation and service guidance
Use product manual M-022, BVT general instructions M-001 and the drawings supplied for the installation. These notes are an overview, not a substitute for the equipment-specific instructions. Installation, commissioning and service must be carried out by trained personnel within the specified service conditions.
Product-specific installation requirements
M-022 covers both flanged and welded connection designs. In each case, the nozzle opening must face the direction of the steam flow. The installation drawing determines the correct nozzle-holder alignment; do not rotate the nozzle arrangement without checking the specified orientation.
Select the external spray-water control valve together with the desuperheater. Keep access available to the water connection and nozzle holder for inspection. Review downstream mixing, evaporation and temperature measurement as part of the complete steam-temperature control system rather than the venturi component alone.
Before commissioning
Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.
Safe access and maintenance planning
Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.
Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.
Frequently asked questions
- How does the BVT-DLV venturi desuperheater work?
- A fixed nozzle injects spray water in the direction of the steam flow. The venturi increases steam velocity around the nozzle, helping droplets evaporate and reducing the risk of water contacting the downstream pipe wall.
- Does the DLV need an external water control valve?
- Yes. The DLV has a fixed nozzle and no moving control parts in its injection assembly. An external spray-water control valve regulates water flow and determines the published rangeability of the arrangement.
- What does the 5 bar pressure-drop value mean?
- B-026 specifies a maximum pressure drop over the nozzle of 5 bar, also stated as 70 psi. This is not the steam-line pressure rating. The connection pressure class and available water-to-steam pressure difference must be reviewed separately.
- How close to saturation can the DLV control temperature?
- B-026 describes control down to 8 °C, or 15 °F, above saturation. The achievable performance must be confirmed for the steam conditions, water control valve, flow range and available evaporation distance.
- What connection sizes and classes are published?
- B-026 lists steam connections up to 6 inches, water connections up to 2 inches and ASME pressure classes 600-2500. Confirm the final configuration and pressure-temperature rating from the order documentation.
- Which installation manual applies?
- Use M-022 together with BVT general instructions M-001 and the supplied drawings. M-022 covers flanged and welded designs and requires the nozzle opening to face the steam flow direction.
Product documentation
Download B-026 BVT-DLV brochure (PDF)
For installation and service, use product manual M-022 together with BVT general instructions M-001 and the documentation supplied for your equipment. Contact BVT for the applicable manual revision, installation drawings and spare parts identification.