BVT-DP2 Probe-Style Desuperheater
The BVT-DP2 is a probe-style steam desuperheater combining an injection nozzle and an integrated water control valve. A diaphragm actuator regulates spray-water injection using the measured downstream temperature. The nozzle creates rotational flow and a cone-shaped spray to improve evaporation in the steam pipe.
How the BVT-DP2 works
Water enters through the flanged water connection and passes through the desuperheater body, which enters the steam pipe at a 45-degree angle. Individual feed holes lead water into the chamber behind the nozzle orifice plate. The water rotates in this chamber before it is injected into the steam flow.
The rotational flow and cone-shaped mist help distribute the injected water and reduce evaporation time. The internal water valve has an equal-percentage characteristic and a published water-control range up to 50:1. This is a water-control specification, not a guarantee of complete-system steam turndown.
The downstream temperature measurement provides the feedback for diaphragm-actuator control. Nozzle selection, available water pressure and the steam operating range must be considered together. The DP2 should not be confused with the DP3, which uses a replaceable spring-loaded NS nozzle and has different published water-valve data.
Applications and selection
Select the DP2 for steam-temperature control where an integrated water valve and probe-style injection arrangement suit the installation. Its compact control arrangement combines water metering and injection rather than relying on a fixed injection nozzle alone.
Provide steam flow, inlet pressure and temperature, the required outlet temperature, water pressure and temperature, pipe dimensions and the proposed temperature-sensor location. Allow sufficient distance for mixing and evaporation, and include drainage in the system layout. The selected pressure class does not by itself establish the permitted pressure-temperature envelope.
Key features
- Integrated water control and rotational injection nozzle.
- Equal-percentage water characteristic.
- Diaphragm-actuator regulation from downstream temperature.
- Hard-faced control plug and injection nozzle for wear resistance.
- Few moving parts and a compact probe-style arrangement.
Specifications
| Capacity | Selected for customer requirements |
|---|---|
| Water characteristic | Equal percentage |
| Water-control range | Up to 50:1 |
| Pressure class | EN PN up to 400; ASME up to 2500 |
| Body material | 11CrMo9-10 |
| Atomization | Rotational water flow and cone-shaped spray |
| Probe entry | 45 degrees into the steam pipe |
| Installation | Horizontal recommended; consult BVT for other orientations |
B-015 does not give a universal design-temperature limit. Confirm the selected materials, pressure-temperature rating, capacity and actuator requirements against the order documentation.
Installation and service guidance
Use product manual M-010, BVT general instructions M-001 and the drawings supplied for the installation. These notes are an overview, not a substitute for the equipment-specific instructions. Installation, commissioning and service must be carried out by trained personnel within the specified service conditions.
Product-specific installation requirements
B-015 recommends horizontal installation; contact BVT for other orientations. The 45-degree probe entry is a design feature and must not be interpreted as permission to install the complete assembly in an arbitrary orientation.
Use clean spray water or condensate and provide the water-quality protection specified for the equipment. M-010 describes nozzle contamination and wear, and requires the unit to be isolated, depressurized and cooled before service. Keep the actuator, stem coupling and nozzle service locations accessible.
Before commissioning
Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.
Safe access and maintenance planning
Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.
Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.
Frequently asked questions
- Does the BVT-DP2 include a water control valve?
- Yes. It combines an injection nozzle with an integrated water control valve. A diaphragm actuator regulates water injection using the downstream steam-temperature measurement.
- How does the DP2 atomize water?
- Feed holes rotate the water in a chamber behind the orifice plate before injection. The resulting rotational flow and cone-shaped spray improve evaporation in the steam flow.
- What does the 50:1 figure describe?
- B-015 lists a water-control range up to 50:1 with an equal-percentage characteristic. It does not establish a guaranteed 50:1 cooling turndown for every steam installation.
- Is the DP2 the same as the DP3?
- No. DP2 uses the rotational injection arrangement described in B-015. DP3 uses a spring-loaded NS nozzle and has separate water-valve specifications. Select each model using its own technical documentation.
- Which installation orientation is recommended?
- Horizontal installation is recommended. Contact BVT for other arrangements, and follow the supplied drawing for the 45-degree probe entry and downstream temperature measurement.
- Which documents apply?
- Use brochure B-015, product manual M-010 and general instructions M-001, together with the equipment-specific drawings and the actuator documentation supplied for the installation.
Product documentation
Download B-015 BVT-DP2 brochure (PDF)
For installation and service, use product manual M-010 together with BVT general instructions M-001 and the documentation supplied for your equipment. Contact BVT for the applicable manual revision, installation drawings and spare parts identification.
Related BVT products
Contact BVT Sweden with the operating conditions and required functionality for application-specific selection.
