        • BVT-TB steam conditioning valve
        • BVT-TBG Steam Conditioning Valve
        • BVT-PB process bypass valve
        • BVT-SC pressure reducing valve
        • BVT-SV stop valve
        • BVT-HB heater bypass valves
        • BVT-BO turbine bypass valve
        • BVT-SCG pressure reduction valve
      • Desuperheaters
        • BVT-DLP steam desuperheater
        • BVT-DLB steam attemperator
        • BVT-DLBS steam attemperator
        • BVT-DLH steam attemperator
        • BVT-DPB1 probe-style attemperator
        • BVT-DP2 probe-style desuperheater
        • BVT-DP3 probe-style desuperheater
        • BVT-DLV venturi desuperheater
      • Actuation & Control
        • BVT-PD pneumatic piston actuator
        • Hydraulics
        • BVT-MSA pneumatic diaphragm actuator
      • Spareparts & Upgrades
        • Spring-loaded Atomizing Nozzles
        • Spare parts and retrofits
        • Pneumatics
        • Hydraulics
        • BVT-Z quick change seat
        • BVT-ZP Zero Passage quick change seat
    • Services & Solutions
      • Plant Engineering
      • Field Service
      • Technical Solutions
      • BVT Remote Assist
      • BVT ranger
    • Success stories
    • Articles
      • Desuperheating
      • Pneumatics
  • About us
    • BVT Sweden
    • Contact
    • Job listings

BVT-PB Process Bypass Valve

Steam conditioning valve for auxiliary and process steam — up to 225 mm seat diameter, ANSI 1500, 575 °C, rangeability of at least 50:1

BVT-PB process bypass valve with forged body, pressure seal bonnet and actuator
BVT-PB process bypass valve. Pressure reduction takes place in the valve trim and in the outlet, where several pressure-reducing pipes are installed.

Overview

The BVT-PB is a steam conditioning valve from BVT Sweden optimized for auxiliary and process steam. Process steam applications range from petrochemical plants to pulp and paper, where the valve is typically installed in parallel to a steam turbine and controls the downstream pressure and temperature.

Pressure reduction takes place in the valve trim as well as in the outlet, where several pressure-reducing pipes are installed. The pressure reduction stages are optimized for the actual operating conditions and for reduced noise. A balanced plug design keeps actuating forces low, and a long cage design reduces wear on trim internals caused by wet steam or particles.

Temperature control

Spray water is introduced in the plug and carried together with the superheated steam through the spray water atomization pipe. The increased velocity, reduced pressure and increased turbulence of the fluid in this pipe hasten the evaporation of the spray water droplets and improve the valve’s desuperheating performance. Water proportioning is handled at the top of the hollow stem.

Because this design does not depend on high steam velocity in the outlet, the valve achieves a rangeability of at least 50:1.

Modified linear characteristic

The BVT-PB uses a modified linear flow characteristic, which allows greater rangeability and better flow control at low flow rates. Over the first ~15% of the stroke, the flow coefficient increases by only 5%.

Applications

Bypass to process

In a typical arrangement, two BVT-PB valves are installed in parallel to a steam turbine together with two BVT-DLP multi-nozzle desuperheaters. Superheated steam is desuperheated by both the valves and the desuperheaters before being output as process steam. Spray water (condensate) is controlled by external spray water control valves and stop valves.

Typical markets

  • Petrochemical plants
  • Pulp and paper mills
  • Combined heat and power (CHP) plants
  • Auxiliary steam systems

Specifications

BVT-PB process bypass valve — technical specifications (source: BVT datasheet B-004)
Valve sizes Up to 225 mm seat diameter (larger seat sizes upon request)
Pressure class Up to ANSI 1500 (higher rating on request)
Design temperature 575 °C as standard (620 °C on request)
Leakage class ANSI Class III
Rangeability At least 50:1
Flow characteristic Modified linear
Regulatory requirements ASME, EN, PED, IBR, CRN. Manufactured under ISO 9001 and ISO 14001.
Materials Forged material adapted to connecting pipe material
Bonnet Pressure seal bonnet
Actuation Pneumatic, hydraulic or electrical
Connections Fully customizable inlet and outlet connections
Options Live load; BT-design

Key features

  • Excellent rangeability of at least 50 to 1.
  • Fully customizable inlet and outlet connections.
  • Complies with ASME, EN and PED.
  • Forged valve body with uniform thickness, and trim design optimized to withstand thermal cycling.
  • Pressure reduction stages optimized for operating conditions and for reduced noise.
  • Balanced plug design requires smaller actuating forces.
  • Pressure seal bonnet for simpler and quicker maintenance — no special tools necessary.
  • Compatible with pneumatic, hydraulic and electrical actuation.
  • Optimized packing design.
  • Long cage design reduces wear on trim internals caused by wet steam or particles.

Actuation options

Pneumatic actuation

BVT valves can be equipped with the BVT-PD linear pneumatic piston actuator, mounted on top of the valve with a coupling to the valve stem. Each actuator is sized to the force requirements of the valve and to the customer’s stroke time and functional requirements. It is also available as an upgrade for existing valves.

A positioner modulates the actuator from a 4–20 mA set-point signal, with volume boosters added where higher stroke speed is needed. By default the actuator has a quick open or quick close function: if the supply pressure drops below a set level, the modulating operation is overridden and the valve is driven to its safe position, using air stored in an air tank (double acting) or a spring (single acting).

BVT-PD pneumatic piston actuator with positioner, air tank and air filter regulator
BVT-PD linear pneumatic actuator.
BVT-PB pneumatic actuation data (BVT-PD)
Types Double acting or single acting (spring open or spring close); modulating or on/off
Air supply 4 – 10 bar
Operating temperature −20 to 80 °C (standard)
Cylinder sizes Up to 900 mm
Protection Components IP65/IP67; cylinder corrosion protection ISO 12944 C4 or C5M; ANSI 316 tubes and fittings
Standard accessories Air filter regulator, positioner, pressure sensing valve for quick function
Optional accessories Volume boosters, solenoid valves, limit switches, position transmitter, top or side mounted hand wheel
Compliance ASME, PED, ISO 9001/14001; ATEX and SIL as option

Electro-hydraulic actuation

Commissioning tools and hydraulic pipes, fittings and hoses are also available.

Electro-hydraulic system layout: HPG, HCP and actuators Schematic of a BVT electro-hydraulic actuation system. The Hydraulic Power Generator on the right is connected to the Hydraulic Control Panel by a pipe run of maximum 40 metres. From the Hydraulic Control Panel a pipe run of maximum 12 metres feeds four actuators: two modulating actuators on BVT valves and two on/off actuators. Each actuator is connected to the pipe run by a flexible hose of 1.5 metres. HPG Hydraulic Power Generator (IPM pump control) HCP Hydraulic Control Panel (IAC positioning) 2 × modulating actuators 2 × on/off actuators Piping HCP to actuators max 12 m Piping HPG to HCP max 40 m
Typical electro-hydraulic arrangement: the HPG supplies hydraulic power to the HCP, which distributes it to the modulating and on/off actuators. The stated pipe and hose lengths are maximum values for a standard system — longer runs require review by BVT Sweden AB. Not to scale.

Installation, commissioning and maintenance

The following summarises requirements from BVT product manual M-005 and general instructions M-001. These are general guidelines — any individual installation may require special considerations, and if the stated pipe distances cannot be achieved, contact BVT Sweden AB for an installation-specific calculation.

Important: all BVT steam valves are designed for dry steam. Wet steam, condensate and magnetite damage valves, and such damage is not covered by warranty. Drains and vent valves must take care of pipe prewarming.

Minimum pipe distances

Non-uniform upstream flow patterns create rotational forces that strain valve parts, and injected water droplets need time and distance to fully evaporate. Where multiple criteria apply, the highest value must be used.

Minimum pipe distances applicable to a BVT-PB process bypass valve (source: BVT general instructions M-001). Ø = pipe diameter, V = steam velocity.
Distance Condition Must exceed
Straight pipe upstream of inlet (L1) Single upstream bend, Ø < 200 mm 1 metre
Single upstream bend, Ø 200–400 mm 5 × Ø
Single upstream bend, Ø > 400 mm 3 × Ø
Multiple upstream bends, Ø < 200 mm 3 metres
Multiple upstream bends, Ø 200–400 mm 15 × Ø
Multiple upstream bends, Ø > 400 mm 9 × Ø
Straight pipe downstream of water injection (L2) BVT-PB, steam-assisted atomization — bypass to process 0.05 s × V, maximum 8 × Ø
Water injection to downstream temperature sensor (L3) Water-to-steam ratio r < 15% 0.2 s × V, maximum 12 metres
Water-to-steam ratio 15% ≤ r < 18% (0.2 + (r − 15%) / 0.3) s × V, maximum 12 metres
Water-to-steam ratio r ≥ 18% 0.3 s × V, maximum 12 metres
Minimum pipe distances around a BVT-PB process bypass valve Distance L2 is the straight pipe downstream of the spray water injection point, ending at the first downstream bend. After that bend the pipe steps down and continues horizontally. Distance L3 is the distance from the spray water injection point to the downstream temperature sensor, measured along the pipe and therefore including the bend. Superheated steam Last upstream bend Conditioned steam BVT-PB Spray water injection (valve outlet) TT Temperature sensor L1 Straight pipe upstream of inlet L2 — straight pipe downstream of injection L3 — injection to temperature sensor
The three minimum distances around a BVT-PB. L1 is measured from the last upstream bend to the valve inlet, while L2 and L3 are both measured from the spray water injection point. Where several criteria apply, the highest value applies. Not to scale.

Avoid multiple bends upstream of the valve, as these cause rotational steam flow.

Spray water connection

For the BVT-PB, the water connection must be the same size as the connecting water pipe, and the installation between the BVT-PB bonnet and the water pipe must be adjusted to avoid bending stress or gaps between flanges. The best result is achieved if BVT specifies the size of the water pipe and flanges 4–6 metres upstream of this connection.

Drainage

Water entering a steam conditioning valve can damage internal parts and disturb downstream temperature measurement, so drains are required both upstream and downstream of the valve. Maximum condensate normally occurs during cold startup and must be considered at the design stage when sizing the drainage system. As an estimate, a water mass of typically 7–14% of the upstream piping weight needs to be removed through the condensate system during startup.

An undersized upstream drainage system that cannot handle condensate from pipe warming during a cold start is the most common cause of valve damage. The drain valve should remain open during startup and any other condition producing condensate, and must stay open until the steam is above saturation + 20 °C. A temperature sensor should always confirm that upstream steam is dry before the valve is opened.

Temperature sensor placement

The downstream temperature sensor must be positioned where it measures the temperature actually being controlled. If it is installed too close to the spray water injection point it may be struck by unevaporated droplets, producing a false low reading and unstable temperature control. No branches, isolation valves or other obstructions may be placed in the steam line between the spray water injection point and the temperature sensor. A higher degree of superheat or a higher water temperature shortens the required distance; lower values lengthen it. BVT can supply a protective shield that encases the sensor, installed with its hole facing downstream.

BVT also recommends installing a temperature sensor and a pressure sensor upstream of the steam conditioning valve, both to confirm dry steam before the valve opens and to support feed-forward outlet temperature control.

Insulation

Any valve intended for hot service must be insulated. Thermal insulation should be applied to all exterior surfaces of the valve body and bonnet, and should help keep the body adequately warm while the valve is closed. Proper insulation minimises heat loss, maintains thermal stability, reduces the risk of condensation and water hammer, and improves personnel safety.

  • Insulate the valve body, inlet and outlet piping, and adjacent flanges.
  • Do not insulate actuators, positioners or other temperature-sensitive electrical equipment — the actuator and its accessories must be protected from excessive heat.
  • Do not cover the yokes or add material that makes removing valve internals difficult.
  • Ensure the insulation does not interfere with plug or stem movement.
  • The insulation must not trap condensate around the valve body.

Insulation also provides noise attenuation. A −10 dBA arrangement uses 1 mm cladding steel plate over 300 mm mineral wool at 200 kg/m³ density. A −15 dBA arrangement adds a heavy self-adhesive noise damping layer (approx. 7 kg/m²) and a 50 mm mineral wool layer between two cladding plates.

Body material temperature limits

Maximum temperature by valve body material (source: BVT general instructions M-001)
Carbon steel (internals Tenifer surface hardened) 480 °C
Low alloy steel 580 °C
13CrMo4-5 / ASTM Gr.12 580 °C
11CrMo9-10 / ASTM Gr.22 580 °C
X10CrMoVNb9-1 / ASTM Gr.91 580 °C
Low alloy steel (internals Cobalt hard faced) 650 °C

Before welding into the pipeline

  • Verify that the installation direction is correct, and that any arrow on the valve body points in the same direction as the flow in the pipe system.
  • Align the pipe ends properly so the valve is not subjected to unnecessary strain.
  • Remove the valve trim before welding the valve into the pipeline.
  • Remove any commissioning tools (hydrotest, blowout, etc.) before welding.
  • Welding and any necessary heat treatment are the contractor’s responsibility and must be performed in compliance with applicable standards by qualified personnel.

Commissioning and steam blowing

Debris generated during installation or major repair can damage valve trim and sealing surfaces, clog spray nozzles and cause improper valve operation. Steam blowing removes loose particles from the pipework, but the procedure itself can severely damage trim parts, so protective equipment such as a blow out tool, blow through tool, dummy nozzles or sacrificial trims must be installed first. BVT must be informed of the planned steam blowing method in advance and can supply the required tools.

Steam blowing operating conditions
Steam temperature 50 – 100 °C above saturation point
Steam velocity More than 50% of maximum steam velocity, and at least 70 m/s
Max. temperature for BVT steam blowing tools 425 °C as standard

If the steam velocity is too low, particles may not be carried along and can fall back into the pipework where they are difficult to detect.

Upstream stop valve

An undersized steam stop valve creates a high pressure drop as it constricts the flow, which in turn gives the steam control valve a non-linear characteristic. Undersized stop valves with a reduced bore upstream of a steam control valve are known to cause noise and vibration due to high vena contracta velocities and non-uniform velocity distribution. An angle-style stop valve can be welded directly to the inlet connection of the BVT-PB as a single unit, but BVT must be informed in advance if such an arrangement is planned.

Maintenance notes

  • Confirm that the pressure vessel is depressurized and sufficiently cooled down before starting any work, and wear protective gloves, clothing and eye-wear.
  • Before maintenance on a valve in an operational facility, a double block-and-bleed configuration must be installed upstream. Each component in the block-and-bleed system must be individually proven for the highest expected pressure.
  • Ensure the packing gland is firmly tightened before pressurizing the valve. Never remove the gland nut or flange while the valve is pressurized.
  • Ensure drain and vent valves are open and discharging.
  • The pressure seal must be replaced after every disassembly.
  • Stem packing rings must be replaced after every disassembly.
  • The valve and yoke must never be lifted using the actuator or eye bolts installed on the actuator.
  • If live load is used, note the compressed height of the belle-ville washer sets before removing the gland yoke nuts.
  • No alteration should be made to any valve without the involvement of BVT service engineers.

Frequently asked questions

What is the BVT-PB process bypass valve?
A steam conditioning valve from BVT Sweden optimized for auxiliary and process steam. It is typically installed in parallel to a steam turbine and controls the downstream pressure and temperature of the steam delivered to process.
Which industries use the BVT-PB?
Process steam applications ranging from petrochemical plants to pulp and paper, as well as auxiliary steam systems and CHP plants where steam bypasses a turbine to process.
What is the rangeability of the BVT-PB?
At least 50 to 1. The desuperheating design does not depend on high steam velocity in the outlet, and the modified linear characteristic gives fine flow control at low openings.
How does the BVT-PB control steam temperature?
Spray water is introduced in the plug and carried with the superheated steam through a spray water atomization pipe, where increased velocity, reduced pressure and turbulence hasten evaporation. Water proportioning is handled at the top of the hollow stem.
Where does pressure reduction take place?
In the valve trim and in the outlet, where several pressure-reducing pipes are installed. The stages are optimized for the operating conditions and for reduced noise.
What sizes and pressure ratings are available?
Up to 225 mm seat diameter (larger on request) and up to ANSI 1500 (higher ratings on request).
What is the maximum design temperature?
575 °C as standard and 620 °C on request.
What leakage class does the BVT-PB meet?
ANSI Class III.
Which standards does it comply with?
ASME, EN, PED, IBR and CRN. BVT Sweden manufactures under ISO 9001 and ISO 14001.
How is the BVT-PB actuated?
Pneumatic, hydraulic or electrical actuation. Pneumatic piston actuators use a 4–10 bar air supply; BVT also supplies electro-hydraulic actuators with HCP and HPG units.
Why does the BVT-PB need only small actuating forces?
It uses a balanced plug design, which reduces the forces the actuator must overcome.
How is the BVT-PB maintained?
The pressure seal bonnet allows simpler and quicker maintenance without special tools. The pressure seal and stem packing rings must be replaced after every disassembly. See product manual M-005.
Is the BVT-PB used together with desuperheaters?
Yes. A typical arrangement uses two BVT-PB valves in parallel to a steam turbine together with two BVT-DLP multi-nozzle desuperheaters, with spray water controlled by external spray water control valves.

Download

Download the BVT-PB process bypass valve brochure (PDF, document B-004)

For disassembly, assembly and actuator installation procedures, refer to product manual M-005 BVT-PB and to the general instructions for BVT valves and desuperheaters in M-001.

Related BVT products

  • BVT-DLP — multi-nozzle steam desuperheater, often installed together with the BVT-PB in bypass-to-process arrangements
  • BVT-TB — angle-style steam conditioning valve for turbine bypass, up to ANSI 4500
  • BVT-SC — pressure reducing valve
  • BVT-SV — stop valve
  • BVT-PD — pneumatic piston actuator

About BVT Sweden

BVT Sweden AB was started with the ambition of becoming world leading in critical applications in process steam and thermal power plant turbine bypass. Based in Säffle, Sweden, BVT Sweden employs experts with over 30 years of experience in turbine bypass, steam conditioning, temperature control, design and manufacturing processes. BVT designs turbine bypass valves and selects actuation to fit each customer’s requirements. Products are optimized on a per-order basis, and include steam conditioning valves, pressure reduction valves, stop valves, desuperheaters and spray water control valves.

Contact BVT Sweden for application-specific sizing and selection.

Source documents: datasheet B-004 BVT-PB, product manual M-005 BVT-PB, general instructions M-001. Last reviewed: 2026-09-25.

Follow us

Facebook
Linkedin

Our partners

HP Valves B.V.
Key Valve Technologies LTD

Factory Support Office

Industrigatan 1-3
661 32 Säffle
SWEDEN

Sales Office

BVT Sweden AB
Körkarlsvägen 8
SE-653 46 Karlstad
Sweden

Factory Address

Industrigatan 1
661 32 Säffle
Sweden

© 2019 BVT Sweden