logo
  • Where we operate
    • Markets
      • Concentrated Solar Power
      • Combined Cycle Power Plants
      • Combined Heat and Power
    • Applications
      • Our Applications
      • Turbine Bypass System
      • Boiler Attemperator
      • Heater Bypass System
      • Condensate Recirculation
      • Deaerator Level Control
      • Boiler Feedwater Startup
      • Boiler Feedwater Pump Recirculation
      • Soot Blower Steam Service
      • Vent to atmosphere
  • What we do
    • Products
      • Our Products
      • Valves
        • BVT-TB steam conditioning valve
        • BVT-TBG Steam Conditioning Valve
        • BVT-PB process bypass valve
        • BVT-SC pressure reducing valve
        • BVT-SV stop valve
        • BVT-HB heater bypass valves
        • BVT-BO turbine bypass valve
        • BVT-SCG pressure reduction valve
      • Desuperheaters
        • BVT-DLP steam desuperheater
        • BVT-DLB steam attemperator
        • BVT-DLBS steam attemperator
        • BVT-DLH steam attemperator
        • BVT-DPB1 probe-style attemperator
        • BVT-DP2 probe-style desuperheater
        • BVT-DP3 probe-style desuperheater
        • BVT-DLV venturi desuperheater
      • Actuation & Control
        • BVT-PD pneumatic piston actuator
        • Hydraulics
        • BVT-MSA pneumatic diaphragm actuator
      • Spareparts & Upgrades
        • Spring-loaded Atomizing Nozzles
        • Spare parts and retrofits
        • Pneumatics
        • Hydraulics
        • BVT-Z quick change seat
        • BVT-ZP Zero Passage quick change seat
    • Services & Solutions
      • Plant Engineering
      • Field Service
      • Technical Solutions
      • BVT Remote Assist
      • BVT ranger
    • Success stories
    • Articles
      • Desuperheating
      • Pneumatics
  • About us
    • BVT Sweden
    • Contact
    • Job listings

BVT-SC Pressure Reducing Valve

Steam pressure reducing valve for turbine systems and vent to atmosphere — up to 500 mm seat diameter, ANSI 4500, 620 °C

BVT-SC pressure reducing valve with forged body and pressure seal bonnet
BVT-SC pressure reducing valve. Pressure is reduced in a perforated cage trim and, where required, in static pressure reduction pipes in the outlet.

Overview

The BVT-SC is a pressure reducing valve from BVT Sweden used in steam turbine systems, typically in vent to atmosphere applications. The valve is placed in a steam pipe branched from the connection between boiler and turbine, allowing the steam to be vented to atmosphere in case of a turbine trip.

The BVT-SC can also be combined with a downstream desuperheater such as the BVT-DLP to perform steam conditioning in installations where downstream straight pipe lengths do not allow for desuperheating in the pressure reducing valve.

Design

Pressure regulation takes place in the valve trim, where a plug reveals a series of perforations in the valve cage. Depending on the pressure drop, a set of static pressure reduction pipes may also be installed in the outlet, providing noise reduction. The pressure reduction stages are optimized for the operating conditions and for reduced noise.

reducing wear on trim internals caused by wet steam or particles.

Designed for maintenance

The bonnet is held by a segmented ring and retainer rather than a bolted flange, so the complete trim — bonnet, plug and stem — is lifted out of the body from above once the actuator and yoke are removed. The valve can stay welded in the pipeline. Gland packings can be supplied with live load (Belleville washer sets) to keep the stem seal tight over time. Step-by-step procedures are given in product manual M-009.

Applications

Vent to atmosphere

On a turbine trip, the BVT-SC opens to vent steam from the boiler-to-turbine line to atmosphere, protecting the boiler from overpressure while keeping noise under control through multi-stage pressure reduction.

Pressure reduction with downstream desuperheating

Where both pressure and temperature must be controlled but the downstream pipe layout is too short for desuperheating in the valve itself, the BVT-SC handles the pressure reduction and a downstream BVT-DLP desuperheater handles the temperature.

Typical markets

  • Combined heat and power (CHP) plants
  • Fossil-fueled and biomass power plants
  • Waste-to-energy plants
  • Industrial steam systems

Specifications

BVT-SC pressure reducing valve — technical specifications (source: BVT datasheet B-008)
Valve sizes Up to 500 mm seat diameter
Pressure class Up to ANSI 4500 (higher rating on request)
Design temperature 620 °C as standard (650 °C on request)
Leakage class ANSI Class III, IV, V, MSS SP 61
Regulatory requirements ASME, EN, PED, IBR, CRN. Manufactured under ISO 9001 and ISO 14001.
Materials Forged material adapted to connecting pipe material
Bonnet Pressure seal bonnet
Actuation Pneumatic, hydraulic or electrical
Connections Fully customizable inlet and outlet connections
Options Quick change type seat; erosion resistant trim with long cage; expanded outlet; live load gland seal packings

Key features

  • Fully customizable inlet and outlet connections.
  • Complies with ASME, EN and PED.
  • Forged valve body with uniform thickness, and trim design optimized to withstand thermal cycling.
  • High shut-off class.
  • Pressure reduction stages optimized for operating conditions and for reduced noise.
  • Balanced plug design requires smaller actuating forces, allowing smaller and pneumatic actuators.
  • Pressure seal bonnet for simpler and quicker maintenance — no special tools necessary.
  • Compatible with pneumatic, hydraulic and electrical actuation.
  • Easily exchangeable seat as an option for further reduced maintenance downtime.
  • Optimized packing design.
  • Long cage design reduces wear on trim internals caused by wet steam or particles by moving the critical pressure drop.

Actuation options

Pneumatic actuation

BVT valves can be equipped with the BVT-PD linear pneumatic piston actuator, mounted on top of the valve with a coupling to the valve stem. Each actuator is sized to the force requirements of the valve and to the customer’s stroke time and functional requirements. It is also available as an upgrade for existing valves.

A positioner modulates the actuator from a 4–20 mA set-point signal, with volume boosters added where higher stroke speed is needed. By default the actuator has a quick open or quick close function: if the supply pressure drops below a set level, the modulating operation is overridden and the valve is driven to its safe position, using air stored in an air tank (double acting) or a spring (single acting).

BVT-PD pneumatic piston actuator with positioner, air tank and air filter regulator
BVT-PD linear pneumatic actuator.
BVT-SC pneumatic actuation data (BVT-PD)
Types Double acting or single acting (spring open or spring close); modulating or on/off
Air supply 4 – 10 bar
Operating temperature −20 to 80 °C (standard)
Cylinder sizes Up to 900 mm
Protection Components IP65/IP67; cylinder corrosion protection ISO 12944 C4 or C5M; ANSI 316 tubes and fittings
Standard accessories Air filter regulator, positioner, pressure sensing valve for quick function
Optional accessories Volume boosters, solenoid valves, limit switches, position transmitter, top or side mounted hand wheel
Compliance ASME, PED, ISO 9001/14001; ATEX and SIL as option

Electro-hydraulic actuation

Commissioning tools and hydraulic pipes, fittings and hoses are also available.

Electro-hydraulic system layout: HPG, HCP and actuators Schematic of a BVT electro-hydraulic actuation system. The Hydraulic Power Generator on the right is connected to the Hydraulic Control Panel by a pipe run of maximum 40 metres. From the Hydraulic Control Panel a pipe run of maximum 12 metres feeds four actuators: two modulating actuators on BVT valves and two on/off actuators. Each actuator is connected to the pipe run by a flexible hose of 1.5 metres. HPG Hydraulic Power Generator (IPM pump control) HCP Hydraulic Control Panel (IAC positioning) 2 × modulating actuators 2 × on/off actuators Piping HCP to actuators max 12 m Piping HPG to HCP max 40 m
Typical electro-hydraulic arrangement: the HPG supplies hydraulic power to the HCP, which distributes it to the modulating and on/off actuators. The stated pipe and hose lengths are maximum values for a standard system — longer runs require review by BVT Sweden AB. Not to scale.

Installation, commissioning and maintenance

from BVT product manual M-009 and general instructions M-001.

Important: all BVT steam valves are designed for dry steam. Wet steam, condensate and magnetite damage valves, and such damage is not covered by warranty. Drains and vent valves must take care of pipe prewarming.

Minimum straight pipe upstream

Non-uniform upstream flow patterns create rotational forces that strain valve parts. The straight pipe upstream of the valve inlet (L1) must therefore exceed the values below. Where multiple criteria apply, the highest value must be used.

Minimum straight pipe upstream of a BVT-SC pressure reducing valve (source: BVT general instructions M-001). Ø = pipe diameter.
Condition L1 must exceed
Single upstream bend, Ø < 200 mm 1 metre
Single upstream bend, Ø 200–400 mm 5 × Ø
Single upstream bend, Ø > 400 mm 3 × Ø
Multiple upstream bends, Ø < 200 mm 3 metres
Multiple upstream bends, Ø 200–400 mm 15 × Ø
Multiple upstream bends, Ø > 400 mm 9 × Ø

Downstream desuperheating

Where the BVT-SC is combined with a downstream desuperheater such as the BVT-DLP, the straight pipe lengths and temperature sensor distances downstream of the spray water injection point are governed by the desuperheater. In vent to atmosphere applications, the outlet pressure reduction pipes and the silencer arrangement must be agreed with BVT Sweden.

Insulation

Any valve intended for hot service must be insulated. Thermal insulation should be applied to all exterior surfaces of the valve body and bonnet, and should help keep the body adequately warm while the valve is closed. Proper insulation minimises heat loss, maintains thermal stability, reduces the risk of condensation and water hammer, and improves personnel safety.

  • Insulate the valve body, inlet and outlet piping, and adjacent flanges.
  • Do not insulate actuators, positioners or other temperature-sensitive electrical equipment — the actuator and its accessories must be protected from excessive heat.
  • Do not cover the yokes or add material that makes removing valve internals difficult.
  • Ensure the insulation does not interfere with plug or stem movement.
  • The insulation must not trap condensate around the valve body.

Insulation also provides noise attenuation. A −10 dBA arrangement uses 1 mm cladding steel plate over 300 mm mineral wool at 200 kg/m³ density. A −15 dBA arrangement adds a heavy self-adhesive noise damping layer (approx. 7 kg/m²) and a 50 mm mineral wool layer between two cladding plates.

Body material temperature limits

Maximum temperature by valve body material (source: BVT general instructions M-001)
Carbon steel (internals Tenifer surface hardened) 480 °C
Low alloy steel 580 °C
13CrMo4-5 / ASTM Gr.12 580 °C
11CrMo9-10 / ASTM Gr.22 580 °C
X10CrMoVNb9-1 / ASTM Gr.91 580 °C
Low alloy steel (internals Cobalt hard faced) 650 °C

Before welding into the pipeline

  • Verify that the installation direction is correct, and that any arrow on the valve body points in the same direction as the flow in the pipe system.
  • Align the pipe ends properly so the valve is not subjected to unnecessary strain.
  • Remove the valve trim before welding the valve into the pipeline.
  • Remove any commissioning tools (hydrotest, blowout, etc.) before welding.
  • Welding and any necessary heat treatment are the contractor’s responsibility and must be performed in compliance with applicable standards by qualified personnel.

Commissioning and steam blowing

Debris generated during installation or major repair can damage valve trim and sealing surfaces and cause improper valve operation. Steam blowing removes loose particles from the pipework, but the procedure itself can severely damage trim parts, so protective equipment such as a blow out tool, blow through tool or sacrificial trims must be installed first. BVT must be informed of the planned steam blowing method in advance and can supply the required tools.

Steam blowing operating conditions
Steam temperature 50 – 100 °C above saturation point
Steam velocity More than 50% of maximum steam velocity, and at least 70 m/s
Max. temperature for BVT steam blowing tools 425 °C as standard

If the steam velocity is too low, particles may not be carried along and can fall back into the pipework where they are difficult to detect.

Maintenance notes

  • Confirm that the pressure vessel is depressurized and sufficiently cooled down before starting any work, and wear protective gloves, clothing and eye-wear.
  • Before maintenance on a valve in an operational facility, a double block-and-bleed configuration must be installed upstream. Each component in the block-and-bleed system must be individually proven for the highest expected pressure.
  • Ensure the packing gland is firmly tightened before pressurizing the valve. Never remove the gland nut or flange while the valve is pressurized.
  • Ensure drain and vent valves are open and discharging.
  • The pressure seal must be replaced after every disassembly.
  • Stem packing rings must be replaced after every disassembly.
  • The valve and yoke must never be lifted using the actuator or eye bolts installed on the actuator.
  • If live load is used, note the compressed height of the belle-ville washer sets before removing the gland yoke nuts.
  • No alteration should be made to any valve without the involvement of BVT service engineers.

Frequently asked questions

What is the BVT-SC pressure reducing valve?
A steam pressure reducing valve from BVT Sweden for steam turbine systems, typically used in vent to atmosphere applications where it vents steam from the boiler-to-turbine line in case of a turbine trip.
Where is the BVT-SC installed?
In a steam pipe branched from the connection between the boiler and the turbine.
How does the BVT-SC reduce pressure?
In the valve trim, where the plug reveals a series of perforations in the valve cage. Depending on the pressure drop, static pressure reduction pipes may also be installed in the outlet for noise reduction.
Can the BVT-SC also control steam temperature?
It can be combined with a downstream desuperheater such as the BVT-DLP where downstream straight pipe lengths do not allow desuperheating in the pressure reducing valve.
What sizes and pressure ratings are available?
Up to 500 mm seat diameter and up to ANSI 4500 (higher ratings on request).
What is the maximum design temperature?
620 °C as standard and 650 °C on request.
What leakage class does the BVT-SC meet?
ANSI Class III, IV or V, or MSS SP 61.
Which standards does it comply with?
ASME, EN, PED, IBR and CRN. BVT Sweden manufactures under ISO 9001 and ISO 14001.
How is the BVT-SC actuated?
Pneumatic, hydraulic or electrical actuation. The balanced plug reduces actuating forces, allowing smaller and pneumatic actuators.
How does the BVT-SC handle wet steam or particles?
An optional long cage moves the critical pressure drop, reducing wear on trim internals. An erosion resistant trim is also available.
How is the BVT-SC maintained?
The pressure seal bonnet allows simpler and quicker maintenance without special tools, and the trim is lifted out from above while the valve stays in the pipeline. The pressure seal and stem packing rings are replaced after every disassembly. A quick change seat is available as an option to further reduce downtime. See product manual M-009.

Download

Download the BVT-SC pressure reducing valve brochure (PDF, document B-008)

refer to product manual M-009 BVT-SC and to the general instructions for BVT valves and desuperheaters in M-001, or contact BVT Sweden.

Related BVT products

  • BVT-TB — steam conditioning valve
  • BVT-PB — process bypass valve
  • BVT-DLP — multi-nozzle steam desuperheater
  • BVT-SV — stop valve
  • BVT-PD — pneumatic piston actuator

About BVT Sweden

BVT Sweden AB was started with the ambition of becoming world leading in critical applications in process steam and thermal power plant turbine bypass. Based in Säffle, Sweden, BVT Sweden employs experts with over 30 years of experience in turbine bypass, steam conditioning, temperature control, design and manufacturing processes. BVT designs turbine bypass valves and selects actuation to fit each customer’s requirements. Products are optimized on a per-order basis, and include steam conditioning valves, pressure reduction valves, stop valves, desuperheaters and spray water control valves.

Contact BVT Sweden for application-specific sizing and selection.

Source documents: datasheet B-008 BVT-SC, product manual M-009 BVT-SC, general instructions M-001.

Follow us

Facebook
Linkedin

Our partners

HP Valves B.V.
Key Valve Technologies LTD

Factory Support Office

Industrigatan 1-3
661 32 Säffle
SWEDEN

Sales Office

BVT Sweden AB
Körkarlsvägen 8
SE-653 46 Karlstad
Sweden

Factory Address

Industrigatan 1
661 32 Säffle
Sweden

© 2019 BVT Sweden