BVT-SCG Pressure Reduction Valve
The BVT-SCG is a globe-style pressure reduction valve for steam turbine systems and vent-to-atmosphere applications. A balanced plug and perforated cage regulate steam pressure. Where temperature reduction is also needed, select a separate downstream desuperheater as part of the system.
How the BVT-SCG works
The moving plug exposes perforations in the valve cage to vary the flow area through the pressure-reducing trim. The balanced plug design reduces the actuator force required to move the valve under steam conditions. The actuator and its accessories are selected to meet the installation's stroke-time and control requirements.
Depending on the selected design, a static pressure stage may be included in the outlet. This distributes the pressure reduction and reduces the pressure drop across the cage, helping manage the noise associated with the trim. Trim selection and connection details are matched to the operating duty.
The SCG controls steam pressure; it does not provide integral spray-water cooling. A downstream desuperheater, such as the BVT-DLP, can be selected when a system also needs temperature control, subject to the available piping and evaporation distance.
Applications and selection
In a vent-to-atmosphere arrangement, a steam line branches from the connection between boiler and turbine. The pressure reduction valve provides a controlled discharge route, including during a turbine trip where that is part of the plant design. The complete system must account for flow, pressure drop, temperature and noise requirements.
For selection, provide normal and transient inlet conditions, required outlet pressure, steam flow range, connection dimensions, required shut-off class and actuator functions. The published maximum size or pressure class alone does not determine the correct trim. BVT can review whether a globe-style SCG or another valve arrangement best suits the installation.
Key features
- Balanced plug design for reduced actuating force.
- Customizable inlet and outlet connections.
- Published complete-valve rangeability up to 25:1.
- Optional quick-change seat to simplify trim replacement.
- Optional long-cage erosion-resistant trim and live-load gland seal packing.
Specifications
| Valve size | Up to 14 inches |
|---|---|
| Pressure class | Up to ANSI 600; higher rating on request |
| Design temperature | Up to 580 °C |
| Leakage class | ANSI Class III, IV or V |
| Complete-valve rangeability | Up to 25:1 |
| Body materials | WCB, WC6 or WC9 |
| Actuation | Pneumatic, electrical or hydraulic |
| Options | Quick-change seat; erosion-resistant long-cage trim; live-load gland seal packing |
Confirm the applicable pressure-temperature rating, material and shut-off requirement for the actual valve. Published product-family maxima are not a guarantee that every maximum can be used simultaneously.
Actuation options
The BVT-SCG can be equipped with pneumatic, electrical or hydraulic actuation. Select the actuator to overcome the valve forces and meet the required stroke time, control function and safe-position requirements. The balanced plug reduces the actuating force needed by the valve.
Pneumatic actuation
BVT supplies pneumatic piston actuators selected for the valve duty. Published options include double-acting and single-acting cylinders, spring-open or spring-close arrangements, and top-mounted or side-mounted handwheels. The valve brochures describe an air supply of 4 to 10 bar; use the actual actuator’s pneumatic diagram for the required setting and permitted limits.
| Cylinder configurations | Double acting or single acting; spring open or spring close |
|---|---|
| Published air supply | 4 to 10 bar, subject to the supplied actuator specification |
| Standard accessory | Air filter regulator |
| Options | Quick-open/close valves, limit switches, position transmitter, air locks and volume boosters |
Electrical and hydraulic alternatives
Electrical and hydraulic actuation are available for the product family. Confirm the final actuator, accessories, control interface and required fail-safe behavior with BVT for the selected valve and operating cases. Do not apply a pneumatic actuator’s air-supply data to another actuator type.
Installation and service guidance
Use product manual M-016, BVT general instructions M-001 and the drawings supplied for the installation. These notes are an overview, not a substitute for the equipment-specific instructions. Installation, commissioning and service must be carried out by trained personnel within the specified service conditions.
Product-specific installation requirements
Verify flow direction, connection alignment and the intended discharge arrangement against the supplied drawings. Ensure that the pipe layout and supports do not impose unintended loads on the valve. Review any downstream desuperheater, temperature measurement and noise-control requirements as separate parts of the system design.
Keep the actuator, stem coupling, gland and bonnet accessible for inspection. Product manual M-016 covers the SCG trim and actuator installation. The valve must not be lifted using the actuator or lifting eyes fitted to the actuator; follow the supplied lifting instructions.
Before commissioning
Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.
Safe access and maintenance planning
Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.
Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.
Frequently asked questions
- What is the BVT-SCG used for?
- It is a globe-style steam pressure reduction valve used in turbine systems, including vent-to-atmosphere applications where steam is discharged through a controlled branch from the boiler-to-turbine line.
- Does the SCG also desuperheat steam?
- The SCG provides pressure reduction. When the system needs spray-water temperature control, a separate downstream desuperheater can be selected. Its piping and evaporation requirements must be included in the installation design.
- How is pressure controlled?
- The plug moves relative to a perforated cage, varying the available steam flow area. A balanced plug reduces actuating forces, and an outlet pressure stage may be included in the selected design.
- What ratings are listed in B-029?
- The brochure lists sizes up to 14 inches, pressure class up to ANSI 600 with higher ratings on request, design temperature up to 580 °C, and complete-valve rangeability up to 25:1. Confirm the final pressure-temperature rating for the selected configuration.
- Which actuator options can be selected?
- Pneumatic, electrical and hydraulic actuation are available. The final choice depends on force, control, stroke-time and required safe-position functions for the valve and application.
- Which manual should be used for servicing?
- Use product manual M-016 and BVT general instructions M-001, together with the order-specific drawings and the separate documentation for the installed actuator and accessories.
Product documentation
Download B-029 BVT-SCG brochure (PDF)
For installation and service, use product manual M-016 together with BVT general instructions M-001 and the documentation supplied for your equipment. Contact BVT for the applicable manual revision, installation drawings and spare parts identification.
Related BVT products
- BVT-TBG steam conditioning valve
- BVT-DLP steam desuperheater
- BVT-SC angle-style pressure reducing valve
Contact BVT Sweden with the operating conditions and required functionality for application-specific selection.