BVT-TBG Steam Conditioning Valve
The BVT-TBG is a globe-style steam conditioning valve that reduces steam pressure and temperature in one assembly. It combines cage-guided pressure control with spring-loaded spray-water atomizing nozzles in the outlet, for process steam and turbine bypass applications.
How the BVT-TBG works
As the valve plug moves, it uncovers a series of perforations in the cage. This changes the available flow area and controls the downstream steam pressure. The balanced plug reduces the actuating force required, allowing the actuator to be selected around the actual control and stroke-time requirements rather than unnecessary unbalanced loads.
Temperature control takes place downstream of the pressure-reducing trim. Spring-loaded nozzles inject cooling water perpendicular to the steam flow in the valve outlet. Nozzle selection, position and sizing are matched to the spray-water duty and steam conditions, with the aim of effective atomization and limiting free water in the downstream piping.
The steam pressure-control function and spray-water temperature-control function work together as part of the bypass or process-steam system. The associated spray-water control valve is selected separately for the required water flow and pressure conditions. BVT offers different water-valve trim designs to address the demands of the installation.
Applications and selection
Use the BVT-TBG where both pressure reduction and desuperheating are required in a globe-style valve arrangement. The B-025 brochure illustrates a low-pressure turbine bypass to a condenser, with a separate spray-water control valve supplied from the condensate system. The same product family is used for process steam conditioning.
A turbine bypass provides a secondary path for superheated steam in parallel with a turbine pressure stage. Selection must account for the downstream pressure and temperature required during the intended operating cases, including turbine trips where applicable. Supply BVT with inlet and outlet conditions, steam and water flows, piping details, required shut-off performance and actuator functionality.
Key features
- Balanced plug for reduced actuating force.
- Spring-loaded spray-water atomizing nozzles in the outlet.
- Customizable inlet and outlet connections.
- Quick-change seat, long-cage erosion-resistant trim and live-load gland packing options.
- Pneumatic, electrical or hydraulic actuation selected for the application.
Specifications
| Valve size | Up to 14 inches |
|---|---|
| Pressure class | Up to ANSI 600; higher rating on request |
| Design temperature | Up to 580 °C |
| Leakage class | ANSI Class III, IV or V |
| Complete-valve rangeability | Up to 25:1 |
| Body materials | WCB, WC6 or WC9 |
| Actuation | Pneumatic, electrical or hydraulic |
| Options | Quick-change seat; erosion-resistant long-cage trim; live-load gland seal packing |
Published limits describe the product family, not a simultaneous pressure-temperature guarantee. The selected material, pressure class and order-specific design determine the permitted operating conditions.
Actuation options
The BVT-TBG can be equipped with pneumatic, electrical or hydraulic actuation. Select the actuator to overcome the valve forces and meet the required stroke time, control function and safe-position requirements. The balanced plug reduces the actuating force needed by the valve.
Pneumatic actuation
BVT supplies pneumatic piston actuators selected for the valve duty. Published options include double-acting and single-acting cylinders, spring-open or spring-close arrangements, and top-mounted or side-mounted handwheels. The valve brochures describe an air supply of 4 to 10 bar; use the actual actuator’s pneumatic diagram for the required setting and permitted limits.
| Cylinder configurations | Double acting or single acting; spring open or spring close |
|---|---|
| Published air supply | 4 to 10 bar, subject to the supplied actuator specification |
| Standard accessory | Air filter regulator |
| Options | Quick-open/close valves, limit switches, position transmitter, air locks and volume boosters |
Electrical and hydraulic alternatives
Electrical and hydraulic actuation are available for the product family. Confirm the final actuator, accessories, control interface and required fail-safe behavior with BVT for the selected valve and operating cases. Do not apply a pneumatic actuator’s air-supply data to another actuator type.
Installation and service guidance
Use product manual M-017, BVT general instructions M-001 and the drawings supplied for the installation. These notes are an overview, not a substitute for the equipment-specific instructions. Installation, commissioning and service must be carried out by trained personnel within the specified service conditions.
Product-specific installation requirements
Confirm the steam flow direction, spray-water connections and pipe arrangement against the supplied drawings. The downstream piping must allow for mixing, evaporation and a representative temperature measurement. Request an installation-specific review if the available straight pipe lengths do not match BVT requirements.
Keep the actuator, stem coupling and nozzle service locations accessible. M-017 covers the TBG trim, bonnet, gland and NS nozzles; use the relevant instructions for the supplied valve rather than assuming that a different steam-conditioning model has the same service procedure. Do not lift the valve using the actuator or its lifting eyes.
Before commissioning
Check the delivered equipment and connections against the order documentation. Confirm the intended operating conditions, installation orientation and the functions of the associated control equipment before starting the system. Keep access available for inspection and servicing. If the proposed installation differs from the supplied drawings or operating conditions, contact BVT before proceeding.
Safe access and maintenance planning
Before service, isolate the equipment from the process and disconnect the applicable electrical, pneumatic or hydraulic supplies. Confirm that pressure-retaining equipment is depressurized and sufficiently cooled. Account for stored energy, including actuator springs and trapped pressure; disconnecting a supply alone does not remove every hazard. Wear the required protective equipment and follow local safety procedures.
Use the product manual for component replacement and service procedures, and identify spare parts from the supplied documentation. Do not alter the equipment or instrument settings without confirming the consequences with BVT. Detailed disassembly instructions and tightening torques belong in the applicable service documentation.
Frequently asked questions
- What does the BVT-TBG steam conditioning valve do?
- It reduces steam pressure through a cage-and-plug trim and reduces steam temperature using spray-water nozzles in the outlet. It is a globe-style valve used for turbine bypass and process steam conditioning.
- How does the TBG differ from the BVT-TB?
- The TBG is globe-style, while the TB is angle-style. Both combine pressure reduction and desuperheating, but their published ratings, layout and configuration must be checked separately. Do not apply TB specifications to a TBG installation.
- What are the published size and temperature limits?
- B-025 lists valve sizes up to 14 inches, pressure class up to ANSI 600 with higher ratings on request, and design temperature up to 580 °C. The actual pressure-temperature envelope is determined by the selected design and material.
- Which actuator types are available?
- Pneumatic, electrical and hydraulic actuators are available. Actuator selection is based on valve force, stroke-time and functional requirements; the balanced plug helps reduce the required actuating force.
- Is spray-water control part of the system design?
- Yes. The TBG has outlet atomizing nozzles, while the associated spray-water control valve must be selected for the water duty. The B-025 bypass-to-condenser example shows a separate water control valve.
- Which documents cover this product?
- Use brochure B-025 for the product overview and published specifications, product manual M-017 for the TBG, and general instructions M-001 together with the drawings supplied for the installation.
Product documentation
Download B-025 BVT-TBG brochure (PDF)
For installation and service, use product manual M-017 together with BVT general instructions M-001 and the documentation supplied for your equipment. Contact BVT for the applicable manual revision, installation drawings and spare parts identification.
Related BVT products
Contact BVT Sweden with the operating conditions and required functionality for application-specific selection.